Descargar Imprimir esta página

emmeti EC Serie Manual De Instalacion Y Uso página 122

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Model EH
Fan coil unit application
Nominal cooling capacity
E.E.R. (*)
Absorbed power (*)
Nominal current (*)
Water side exchanger nominal water flow
Motor-driven pump useful static pressure
Sound power level
Sound pressure
Nominal thermal capacity
COP
Absorbed power (*)
Nominal current (*)
Radiant panel application
Nominal cooling capacity
E.E.R.
E.S.E.E.R.
Absorbed power (*)
Nominal current (*)
Nominal thermal capacity
COP (**)
Absorbed power
Nominal current (*)
Sound power level
Thermal capacity
COP
Absorbed power
Electrical power supply
Maximum current
Starting current
Motor-driven pump absorbed power
Motor-driven pump absorbed current
Fans
Scroll/step compressor
Exchanger water contents
Water tank contents
Shipping Weight
Water connections
Dimensions
Width (L)
Height (H)
Depth (P)
(1) In the following conditions: condenser input air temperature 35°C; chilled water
temperature 7°C; temperature differential at evaporator 5°C.
(2) In the following conditions: condenser inlet air temperature 35°C; chilled water temperature
18°C; temperature differential at evaporator 5°C.
(3) In the following conditions: evaporator inlet air temperature 7°C; hot water temperature
45°C; temperature differential at the condenser 5°C.
(4) In the following conditions: evaporator inlet air temperature 7°C B.S., 6°C B.U.; hot water
temperature 35°C; temperature differential at the condenser 5°C.
(7) In the following conditions: evaporator inlet air temperature -7°C B.S., 6°C B.U.; hot water
temperature 35°C with the same capacity as condition (4).
Sound pressure level in dB(A), measured at a distance of 5 m from the unit, with a directionality
factor of 2.
Sound power level in dB(A) on the basis of measurements made in compliance with the UNI
EN-ISO 3744 standard and Eurovent 8/1.
E.S.E.E.R. (European Sesonal EER).
(*) Without motor-driven pump.
(**) Reference for the tax credit for the French market (according to EN 14511).
Rif.
1510 T
1
kW
15,27
1
2,73
1
kW
5,58
1
A
12,9
1
l/h
2626
1
kPa
70
1
dB(A)
72
1
dB(A)
50
3
kW
16,80
3
3,05
3
kW
5,50
3
A
15,0
2
kW
20,20
2
3,31
1
3,15
2
kW
6,10
2
A
13,3
4
kW
17,20
4
3,74
4
kW
4,60
4
A
10,2
4
dB(A)
73
7
kW
11,38
7
2,41
7
kW
4,72
V-ph-Hz
400-3-50
A
18,1
A
79
kW
0,40
A
2,1
2
1/1
l
1,33
l
35
Kg
215
Ø
1 ½ "G
mm
1522
mm
1090
mm
580
122
1710 T
2210 T
2410 T
17,40
22,30
23,64
2,70
2,81
6,45
7,93
15
18
2993
3836
57
55
72
75
50
52
17,90
23,66
26,14
2,94
2,94
6,10
8,06
14,5
18,3
23,40
30,50
31,90
3,30
3,43
3,11
3,44
7,10
8,90
10,20
16,2
19,1
18,10
23,96
26,30
3,77
3,82
4,80
6,27
14,0
15,8
73
78,4
11,98
15,74
17,86
2,51
2,52
4,77
6,25
400-3-50
400-3-50
400-3-50
19,1
23,1
105
116
0,40
4,40
2,1
2,1
2
2
1/1
1/1
1,33
1,90
35
45
225
278
1 ½ "G
1 ½ "G
1 ½ "G
1522
1522
1090
1290
580
600
ALLEGATI
2710 T
3010 T
26,33
28,58
2,54
2,61
2,44
9,38
10,10
11,70
21,3
21
24,2
4066
4529
4916
56
48
90
75
76
76
52
53
53
30,69
34,42
2,92
3,07
3,10
8,90
10,00
11,11
20,5
20,7
21,0
35,30
37,9
3,13
3,24
2,80
3,09
3,18
2,90
10,90
13,5
18,5
23,2
31,19
35,7
3,76
3,82
7,00
8,16
15,3
19,2
78,4
79
20,45
2,48
2,47
7,21
8,27
400-3-50
400-3-50
24,8
27,1
29,2
123
122
134
0,40
0,40
0,70
2,1
2,1
2,2
2
2
2
1/1
1/1
1/1
2,20
2,40
2,60
45
45
45
288
320
380
1 ½ "G
1 ½ "G
1522
1822
1822
1290
1510
1510
600
695
695
L
P
-
-
-
-
-
-
-
-