ELECTRICAL REQUIREMENTS
For 28" wide Tumblers
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a qualified electrical contractor in accordance with all
applicable local and national requirements.
NOTE: DO NOT use aluminum wire.
Heat Source
Gas
Gas
Gas
Gas
Electric
Electric
Electric
Electric
Electric
Electric
Electric
Electric
Electric
Amp Rating
104 AMP 92 AMP 62 AMP 55 AMP 27 AMP 91 AMP 55 AMP 34 AMP 31 AMP
Circuit Breaker
125 AMP 100 AMP 70 AMP 60 AMP 30 AMP 100 AMP 60 AMP 40 AMP 35 AMP
Poles
Minimum Wire Size
Per Canadian Elec.
Code C22.1
Minimum Wire Size Per
Canadian Elec. Code C22.1
Disconnect Switch
Fusetron
Circuit Breaker
No. of Poles
34
Electrical Specs
120/60/1
208-240/60/1
240/50/1
120/50/1
208/60/1
240/60/1
240/50/1
208/60/3
240/50/3
240/60/3
380/50/3
415/50/3
480/60/3
ELECTRIC DRYING TUMBLERS
240V
208V
208V
60 HZ
60 HZ
60 HZ
1 PH
1 PH
3 PH
2
2
1 AWG
2 AWG
4 AWG
GAS DRYING TUMBLERS
120V 1 Phase
60 Hz.
14 AWG
15 AMP
15 AMP
15 AMP
1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Wires Required and Terminal Block Connections
L1, Neutral, and ground
L1, L2, Neutral, and ground
L1, Neutral, and ground
L1, Neutral, and ground
L1, Neutral, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, Neutral, and ground
L1, L2, L3, Neutral, and ground
L1, L2, L3, and ground
Table 4
480V
240V
60 HZ
60 HZ
3 PH
3 PH
3
3
3
6 AWG 10 AWG 2 AWG
Table 5
208/240V 1 Phase
60 Hz.
16 AWG
USE CIRCUIT BREAKER ONLY
15 AMP
2
Table 6
L1, L2, and ground
L1, L2, and ground
L1, L2, and ground
240V
240V
50 HZ
50 HZ
1 PH
3 PH
2
3
6 AWG
240V 1 Phase
50 Hz.
16 AWG
15 AMP
2
380V
415V
50 HZ
50 HZ
3 PH
3 PH
3
3
8 AWG
8 AWG
120V 1 Phase
30 Hz.
14 AWG
15 AMP
2