VERTICAL EXHAUST INSTALLATION
WALL
CONNECT TO
TUMBLER
2" (5.1 cm)
MINIMUM
WALL
2" (5.1 cm)
MINIMUM
NO SCREEN
OR CAP
AIR OUT
M414545
NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL
OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm)
LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE
PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING.
L
K
DUCT
28" WIDE
STATION
GAS & ELEC.
A
7" (17.8 cm)
B
10" (25.4 cm)
C
12" (30.5 cm)
D
14" (35.6 cm)
E
16" (40.6 cm)
F
18" (45.7 cm)
G
19" (48.3 cm)
H
20" (50.8 cm)
I
22" (55.9 cm)
J
23" (58.4 cm)
K
24" (61.0 cm)
L
25" (63.5 cm)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
HORIZONTAL EXHAUST INSTALLATION
CONNECT TO
TUMBLER
EXHAUST AIR FLOW
MAXIMUM LENGTH OF
DUCT 14 FEET
(4.3 m)
NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL
OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm)
LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE
PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING.
Figure 4
J
I
H
G
F
MINIMUM DIAMETER
30 LB.
GAS & ELEC.
10" (25.4 cm)
12" (30.5 cm)
15" (38.1 cm)
17" (43.2 cm)
19" (48.3 cm)
21" (53.3 cm)
23" (58.4 cm)
25" (63.5 cm)
26" (66.0 cm)
27" (68.6 cm)
29" (73.9 cm)
30" (76.2 cm)
Figure 5
T030IE3B
INSPECTION OR
CLEANOUT COVER
E
D
C
B
A
45˚
30 LB. STEAM
10" (25.4 cm)
14" (35.6 cm)
17" (43.2 cm)
20" (50.8 cm)
22" (55.9 cm)
24" (61.0 cm)
26" (66.0 cm)
28" (71.1 cm)
30" (76.2 cm)
31" (78.0 cm)
33" (83.8 cm)
34" (86.4 cm)
WALL
2" (5.1 cm)
MINIMUM
EXHAUST
OUTLET
NO SCREEN
OR CAP
T056IE3B
23