OPERATION AND LOGICS

IGNITION
Once you have checked the "basic instructions" listed above, press the
15 minutes are available for the ignition phase. After ignition and having reached the control temperature, the generator stops
the ignition phase and passes to STARTING.
STARTING
During the start-up phase, the generator stabilises combustion, increasing it progressively, then switching to WORK mode.
WORK
During the work phase, the generator reaches the set power; see following item.
ADJUSTMENT SET POWER
Set the operating power from 1 to 5.
Power 1 = minimum level - Power 5 = maximum level.
ADJUSTMENT SET TEMPERATURE H2O
Set the boiler temperature between 65 - 80°C .
PUMP OPERATION
The pump activates water circulation when the in the generator the t° of the water reaches 60°C. As the pump always functions
above 60°, an always open heating area is recommended to make product functioning increasingly uniform, preventing
overheating blocks. Normally this area is de ned "Safety zone".
BURNING POT CLEANING
At pre-set intervals the generator performs the brazier cleaning, switching the machine o .
When the cleaning phase is nished, the generator will re-start automatically and continue its work back to the power level
selected.
MODULATION and H-OFF
As the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum
power.
If the temperature increases beyond the set point, it will automatically switch o indicating H OFF and will automatically go
back on when the temperature drops below the set point.
SWITCH OFF
Press key 1 for three seconds.
When the operation has been performed, the appliance automatically enters the switch- o phase, blocking the supply of
pellets.
The ue gas exhaust motor will remain on until the generator temperature has dropped below the factory parameters.
RE IGNITION
The genertor can be re-ignited both automatically or manually, when the cooling cycle conditions and the preset timer have
been satis ed.
for more than two seconds to turn on the generator.