DISPLAY
OFF
START
PELLET FEEDING
IGNITION
START UP
WORK
MODULATION
BURNING POT
CLEANING
BURNING POT
CLEANING VACUUM
FINAL CLEANING
STAND BY
WAITING COOLING
HOFF
WAITING BLACK OUT
ANTI FREEZE
ANTILOCK
AUTO BLOW
EXCHANGER BLOCKED
DISPLAY
Generatore spento
The start-up phase is in progress
Continuous pellet feeding is in progress during the ignition phase
The ignition phase is in progress
The start-up phase is in progress
The normal work phase is in progress
The stove is working at minimum
Automatic burn pot cleaning is in progress
It's going to clean the brazier - insu cient cause depression.
The nal cleaning is in progress
Stove o waiting for re-ignition due to an external thermostat
The stove will only re-start when the external thermostat makes a request
A new ignition is attempted when the generator has just been switched o when the generator switches o , it
is necessary to wait for the complete shutdown of the engine smokes, then clean the burn pot. The stove can
only be re-ignited when these operations have been performed.
Stove o due to water temperature over set
As soon as the water temperature drops below the pre-set parameters, the stove will switch back on
The stove is cooling after a power cut.
Once cooling is completed it will re-start automatically
The anti-freeze function is in progress as the H2O t° is below the factory set threshold
the pump is active until the water reaches the pre-set factory parameter +2°C
The pump antilock function is in progress (only if the stove has been in an OFF state for at least 96 hours);
the pump is activated for the time pre-set by the manufacturer, in order to prevent it from blocking
The automatic blow is active
The cleaning of the heat exchanger is blocked
EXPLANATION
Indicates the presence of an alarm.
DISPLAYS
REASON
ALARMS
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression
sensor.
The alarm can be reset by pressing key 1 for 3 seconds only
if the fumes motor has stopped and if 15 minutes have
elapsed from when the alarm was displayed.
ENGLISH
RESOLUTION
79