ADDITIONAL ROOM THERMOSTAT

PLEASE NOTE : Installation must be performed by an authorised technician
Is it possible to thermostat a room adjacent to the room where it was placed the generator just connecting a room thermostat
according to the procedure described in the next step (it is advisable to position the optional mechanical thermostat at a height
of 1.50 m from the oor) . The generator functioning with the external thermostat connected to the STBY terminal can be
di erent on the basis of the activation or disabling of the STBY function.
The STBY clamp leaves the factory jumpered, therefore it is always with closed contact (on request).

ADDITIONAL ROOM THERMOSTAT FUNCTIONING WITH STBY ACTIVE STBY ON

When the contact or the external thermostat is satis ed (open contact / temperature reached), the generator will switch o . As
soon as the contact or external thermostat switches to the "not satis ed" status (closed contact/temperature to be reached) it
will re-ignite.
PLEASE NOTE: the generator operation depends on the temperature of the water inside the thermal-product and
relevant factory setting. If the generator is in H OFF (water temperature reached), any additional contact or thermostat request
will be ignored.

OPERATION OF THE AMBIENT ADDITIONAL THERMOSTAT WITH STBY DISABLED STBY OFF

When the contact or external thermostat is satis ed (open contact / temperature reached), the generator will go to minimum.
As soon as the contact or external thermostat switches to the "not satis ed" status (closed contact / temperature to be reached)
the generator will start to work again at the pre-set power.
PLEASE NOTE: the generator operation depends on the temperature of the water inside the general and relevant factory
setting. If the generator is in H OFF (water temperature reached), any additional contact or additional thermostat request will
be ignored.
ADDITIONAL ROOM THERMOSTAT INSTALLATION
Š Switch the appliance o using the master switch positioned on the rear of the generator.
Š Remove the plug from the socket.
Š Refer to the electrical diagram to connect the two thermostat cables onto the relative clamps positioned on the rear of the
machine, one is red and the other one is black (STBY clamp).

AUX

Connection reserved for the productor's conveyed waves accessories.
Contact the dealer for further details.
STBY
AUX
HP30
70
70
H
AUX
STBY
ENGLISH
HP15 - 22