1.6 Electrical specifi cations
Supply voltage 230 V~, 50 – 60 Hz
Power consumption
Rated current capacity
Fuse protection (mains network)
Protection class
Fault-current safety switch PRCD
with low-voltage release
Supply voltage 115 V~, 50 – 60 Hz
Power consumption
Rated current capacity
Fuse protection (mains network)
Protection class
Fault-current safety switch PRCD
with low-voltage release
1.7 Dimensions (L × W × H)
Drive unit
REMS Simplex 2, drill stand
REMS Titan, drill stand
1.8 Weights
Drive unit
REMS Simplex 2, drill stand
REMS Titan, drill stand
1.9 Noise emissions
Sound pressure level
Operating sound level
K = 3 dB (A)
1.10 Vibrations
Weighted effective value of acceleration
K = 1.5 m/s²
The indicated weighted effective value of acceleration has been measured against standard test procedures and can be used by way of comparison with another
device. The indicated weighted effective value of acceleration can also be used as a preliminary evaluation of the exposure.
CAUTION
CAUTION
The indicated weighted effective value of acceleration can differ during operation from the indicated value, dependent on the manner in which the device is used.
Dependent upon the actual conditions of use (periodic duty) it may be necessary to establish safety precautions for the protection of the operator.

2 Initial startup

2.1 Electrical connection
WARNING
Caution: Mains voltage present! Before connecting the power tool, check
whether the voltage given on the rating plate corresponds to the mains voltage.
Only use sockets/extension leads with a functioning protected earth contact.
The function of the PRCD fault current circuit breaker (19)) must be checked
every time before start-up:
1. Plug the mains plug into the socket.
2. Press the RESET button (17), the PRCD control lamp (16) lights red
(operating state).
3. Pull out the mains plug, the PRCD control lamp (16) must go out.
4. Plug the mains plug back into the socket.
5. Press the RESET button (17), the PRCD control lamp (16) lights red
(operating state).
6. Press the TEST button (18), the PRCD control lamp (16) must go out.
7. Press the RESET button (17) again, the PRCD control lamp (16) lights red.
The electric diamond core drilling machine is ready for operation.
WARNING
If the described functions of the PRCD fault current circuit breaker (19) are not
fulfi lled, the device may not be used. There is a danger of electric shock. The
PRCD fault current circuit breaker tests the connected device, not the installa-
tion before the socket nor interconnected extension leads or cable reels.
On building sites, in a wet environment, indoors and outdoors or under similar
installation conditions, only operate the electric diamond core drilling machine
on the mains with a fault current protected switch (FI breaker) which interrupts
the power supply as soon as the leakage current to earth exceeds 30 mA for
200 ms. When using an extension lead, a cable cross section suitable for the
power of the electric diamond core drilling machine must be chosen.
2.2 REMS Picus drive units
The REMS Picus drive units are universally applicable for both dry and wet
drilling, either manually controlled (Picus S1, Picus S3 and Picus SR) or with
drill upright. The combined drill crown connection of the drive spindle (11) of
REMS Picus S1, Picus S3 and Picus SR allows both the direct mounting of
diamond core drill crowns with internal thread UNC 1¼ and with external thread
G ½. The Picus S1, Picus S3 and Picus SR drive machines are not delivered
with the water feeding device (15) pre-assembled but loose. The adapter for
20
Picus S1
Picus S3
1850 W
2200 W
8.4 A
10 A
10 A (B)
16 A (B)
l
l
10 mA
10 mA
1700 W
2050 W
15 A
18 A
20 A
25 A
l
l
6 mA
6 mA
450×160×100 mm
550×160×105 mm
(17.7"×6.3"×3.9")
(21.6"×6.3"×4.1")
435×245×805 mm (17.1"×9.6"×31.7")
360×555×1050 mm (14.2"×21.8"×41.3")
5.2 kg (11.5 lb)
7.4 kg (16.3 lb)
12.0 kg (26.4 lb)
19.5 kg (43.0 lb)
90 dB (A)
90 dB (A)
103 dB (A)
103 dB (A)
2.5 m/s²
2.5 m/s²
Picus S2/3,5
3420 W
16 A
16 A (B)
l
10 mA
2820 W
25 A
25 A
l
6 mA
490×205×150 mm
(19.3"×8.1"×5.9")
14.4 kg (31.7 lb)
91 dB (A)
104 dB (A)
2.5 m/s²
the water connection on the Picus S1, Picus S3 and Picus SR drive machines
is closed by a cover (14). In this condition the drive machines (Picus S1, Picus
S3 and Picus SR) are used for dry drilling. The water feed device is already
pre-assembled on the REMS Picus S2/3,5. For wet drilling, see 2.5.
The drive-unit turning speed required for cost-effective core drilling depends
on the diameter of the diamond core drilling crown. Select the turning speed
of the drive unit in such a way that the peripheral speed (cutting speed) of the
diamond core drilling crown runs within a range between 2 and 4 m/s. It is of
course possible to carry out drilling operations outside this optimum range,
albeit subject to reductions in the operating speed and/or service life of the
diamond core drilling crown. Higher peripheral speed apply in masonry.
The turning speed of the REMS Picus S1 is adjusted to a fi xed setting. From
a drilling diameter of 62 mm, the REMS Picus S1 operates in concrete in the
optimum peripheral speed range, which always remains inside acceptable limits
when smaller diameters are being handled. The attachment method used with
the diamond-tipped segments of the REMS Universal diamond core drilling
crown has been modifi ed so that smaller diameters can also be drilled effi ciently
with the REMS Picus S1.
The turning speed of the REMS Picus S3 can be selected by means of a three-
speed stepped drive to ensure that in concrete it always operates within the
optimum drilling speed range. The correct speed can be taken from the machine
rating plate (Fig. 7) of the REMS Picus S3. The fi rst column of the table shown
there covers speeds 1 to 3, the second column shows the corresponding turning
speeds, the third column the core bit diameters for masonry and the fourth
column contains core bit diameters for steel-reinforced concrete. It shows, for
example, that a Ø 102 mm core-drilling operation in masonry should be carried
out in third speed, while drilling into steel-reinforced concrete requires the use
of fi rst speed.
The turning speed of REMS Picus S2/3,5 can be selected by a 2-step switching
gear so that it always drills in an optimum area. The right gear can be read
from the rating plate (Fig. 8) of REMS Picus S2/3,5. The table there shows
gears 1 and 2 in the fi rst column and the corresponding speeds in the second
column and the drill crown diameters for masonry and steel-reinforced concrete
in the third column.
The rotation of the REMS Picus SR can be selected via a 2-gear stepped drive
in combination with a stepless electronic speed regulation to ensure that it always
operates within the optimum drilling range. The correct speed can be taken from
the table (Fig. 9). The correct gear step is selected at the handle grip (39), the
correct rotation via the electronic speed regulation at the dial (57). The electronic
speed regulation keeps the selected speed largely constant also under load.
eng
Picus SR
2200 W
9.6 A
16 A (B)
l
10 mA
2200 W
19 A
25 A
l
6 mA
590×110×145 mm
(23.2"×4.3"×5.7")
6.4 kg (14.1 lb)
91 dB (A)
104 dB (A)
2.5 m/s²

Publicidad

Tabla de contenido
loading