KIT FACILE - ENGLISH
ASSEMBLY AND INSTALLATION MANUAL
B1 KIT FACILE INSTALLATION
B1.1 Before the installation
Check for the compliance of the hydraulic distribution system and the installation of the filter to local
regulations. The manufacturer disclaims all responsibility for damage to persons or things caused by
improper installation of the filter and/or the installation of the filter in a waterworks not compliant with
local regulations.
KIT FACILE is not equipped, by standard, with any flooding-control system or other devices able to detect,
control or alarm in case of runaway water losses. In case, consider, apart, an adequate anti flooding device.
Do not install KIT FACILE downstream of boilers or in devices involving the transit, inside the filter, of water
at higher than 30°C temperature.
B1.2 Requirements for the place of installation
KIT FACILE must be installed indoor, in an hygienically suitable place, dry and clean, protected from frost,
exposure to sunlight, moisture, atmospheric agent (rain, snow and hail). Do not install KIT FACILE in wells,
near drains, or in smelly places. Do not install where any kind of chemical vapours or gas and fumes may be
present. Avoid installation in tight spaces which cannot allow easy ordinary and extraordinary maintenance
In succession the limit values of the allowed environmental parameters for the KIT FACILE installation:
Ambient temperature (min./max.), °C:
5 – 40
B1.3 In case of installation of KIT FACILE with a water softener
If KIT FACILE is installed with a water softener equipped with a mixing valve (e.g. BravoCAB) you MUST set
the water hardness using the mixing valve of the water softner closing completely the mixing valve installed
on KIT FACILE (turn the hardness mixing valve in the direction "-" until it stops).
To check water hardness use the Acqua Brevetti kit test for hardness (cod. 48105001) sampling water
upstream and downstream of the water softener. If KIT FACILE is equipped with sampling taps use them for
the water hardness check.
B1.4 Installation of sampling taps (not included with KIT FACILE)
The standard endowement of KIT FACILE does not include the sampling taps (N°2) but two ½" stoppers. If
you want to install the sampling taps replace the stoppers.
B1.5 Hydraulic checks after installation
After opening water upstream of the equipment check for leaks.
Verify for the proper installation in order to facilitate maintenance.
In case of doubt please contact Acqua Brevetti s.r.l. (Tel. +39.(0)49.8973432, e-mail: info@acquabrevetti.it).
MAN145