Items Supplied; Technical Data - Hilti PM 2-PE Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
The PM 2-PE is characterized by its ease of operation and use, its robust plastic casing and its ease of
transport due to its compact dimensions and light weight. When in normal operating mode, the tool switches
itself off after 15 minutes. Sustained operating mode is possible by switching on, switching off and switching
on again within 3 seconds.
3.4
Information displayed during operation
Malfunction
LED
Laser beam
3.5

Items supplied

1 PM 2-PE point laser, 1 pouch, 4 batteries, 1 set of operating instructions, 1 manufacturer's certificate.
4
Accessories
Designation
Tripod
Target plate
Telescopic brace
Clamp holder
Laser visibility glasses
5

Technical data

Range of the points
Accuracy at 10 m (33 ft)
Self-leveling time
Laser class
Beam diameter
Self-leveling range
*2288653*
Possible cause
LED does not show
LED shows constantly
LED flashes twice every 10 sec-
onds
Laser beam flashes twice every 10
seconds
The laser beam flashes five times
and then remains permanently on.
Laser beam flashes rapidly
Designation
PMA 20
•/•
PMA 54/55
•/•
PUA 10
•/•
PMA 93
•/•
PUA 60
The laser visibility glasses are not protective
glasses and thus do not protect the eyes from
laser beams. They restrict color vision, so it is not
permissible to wear them while participating in
traffic on public roads. Their use is permissible
only for working with the PM 2-PE.
Distance 5 m (16.4 ft)
Distance 20 m (65.6 ft)
2288653
Action to be taken
▶ The tool is switched off.
▶ The batteries are exhausted.
▶ The batteries are inserted
incorrectly.
▶ The laser beam is switched on.
The tool is in operation.
▶ The batteries are almost ex-
hausted.
▶ The batteries are almost ex-
hausted.
▶ Automatic power-off has been
deactivated.
▶ The tool cannot level itself.
Description
30 m
(98 ft - 10 in)
±1.5 mm
(±0.06 in)
3 s
Class 2, visible, 620 - 690 nm, ±10 nm
(IEC 60825-1:2014); class II (CFR 21
§1040.10 and 1040.11) (FDA)
< 4 mm
(< 0.2 in)
< 16 mm
(< 0.6 in)
± 4°