2.3 IDENTIFICATION
Table 2.1: Identification of the CFW700 inverters
Model Identification
Product
Rated
Number
and
series
Size
output
of power
current
phases
Ex.: CFW700
A
03P6
T
Refer to table 2.2.
NB = without dynamic braking (valid only for size
E inverters).
DB = with dynamic braking.
(2)
20 = IP20
CFW700
21 = IP21 (not available for size E inverters).
N1 = Nema1 enclosure (UL Type 1) (protection degree according to
IEC: IP21 for sizes A, B and C and IP20 for sizes D and E).
Blank = it is not in accordance with the standard conducted emission levels.
C3 = according to category 3 (C3) of IEC 61800-3, with built-in RFI filter.
Notes:
(1) The options available for each model are shown in table 2.2.
(2) This option is not available for size D inverters (the standard product is Nema1).
(3) This option is not available for size A inverters with the N1 option (Nema1 enclosure) or IP21.
Table 2.2: Options available for each model according to the size, power supply, rated current and
Rated output
Size
current for ND
overload
06P0 = 6.0 A
A
07P0 = 7.0 A
06P0 = 6.0 A
A
07P0 = 7.0 A
10P0 = 10 A
07P0 = 7.0 A
10P0 = 10 A
A
13P0 = 13 A
16P0 = 16 A
24P0 = 24 A
B
28P0 = 28 A
33P5 = 33.5 A
45P0 = 45 A
C
54P0 = 54 A
70P0 = 70 A
86P0 = 86 A
D
0105 = 105 A
0142 = 142 A
E
0180 = 180 A
0211 = 211 A
03P6 = 3.6 A
05P0 = 5.0 A
A
07P0 = 7.0 A
10P0 = 10 A
13P5 = 13.5 A
17P0 = 17 A
B
24P0 = 24 A
31P0 = 31 A
38P0 = 38 A
C
45P0 = 45 A
58P5 = 58.5 A
70P5 = 70.5 A
D
88P0 = 88 A
0105 = 105 A
0142 = 142 A
E
0180 = 180 A
0211 = 211 A
(1)
(1)
Braking
Enclosure
Rated
voltage
4
DB
20
voltage of the inverter
Number of
Rated voltage
power phases
B = single-phase or
2 = 200...240 V
three-phase
S = Single-phase
2 = 200...240 V
2 = 200...240 V
T = three-phase
2 = 220...230 V
T = three-phase
4 = 380-480 V
- English -
General Instructions
Conducted
Safety
External
Special
emission
stop
control
hardware
(1)
(3)
voltage
version
level
C3
Y1
W1
---
Blank = standard.
Hxx or Kxx = special
hardware.
Blank = not available.
W1 = 24 Vdc power supply,
independent of the control voltage.
Blank = not available.
Y1 = with safety stop function according to
EN 954-1/ISO 13849-1, category 3.
Available options for the remaining identification
codes of the inverters
(standard product is shown in bold)
Enclosure
Conducted emission
Braking
(protection
degree)
DB
20, 21 or N1
DB
20, 21 or N1
Blank or C3
20, 21 or N1
DB
Blank or C3
21 or N1
NB or DB
20 or N1
20, 21 or N1
DB
Blank or C3
21 or N1
NB or DB
20 or N1
CFW700 | 11
Special
software
version
--
Blank =
standard.
Sx =
special
software.
level
Blank
C3
C3
C3