Appendix B / Anexo B
Notes:
(1) The external RFI filters presented in the table B.6 have been chosen based on the inverter rated
input current specified for ND (normal duty cycle) application, and 50 °C inverter surrounding ambient
temperature. In order to optimize it, consider the inverter input current and its surrounding air temperature
in the application to define the rated current of the external RFI filter to be used. For further information,
consult EPCOS.
(2) It is possible to use longer length; however, a specific test is required.
(3) Standard cabinet without additional EMC measures. It is possible to meet the C1 category radiated
emission levels by adding EMC accessories to the cabinet. In this case, it is required to perform a specific
test to verify the emission levels.
(4) For 45 °C surrounding inverter and filter temperature, and steady output current greater than 172 Arms,
it is necessary to use the B84143B0250S020 filter.
(5) For 40 °C surrounding inverter and filter temperature, and heavy overload duty cycle (HD, output current
< 180 Arms), it is possible to use the B84143B0180S020 filter.
(6) It is necessary to use a metallic cabinet and a Würth Elektronik WE74270191 toroid per phase at the
inverter input.
Notas:
(1) Los filtros RFI externos presentados en la tabla B.6 fueron elegidos con base en la corriente de entrada
nominal del convertidor especificada para aplicación ND (régimen de sobrecarga normal) y temperatura
ambiente alrededor del convertidor de 50 °C. Para optimizar, considerar que la corriente de entrada del
convertidor y la temperatura ambiente alrededor del convertidor en la aplicación para definir la corriente
nominal del filtro RFI externo a utilizarse. Para más informaciones consultar la empresa EPCOS.
(2) Es posible utilizar longitudes mayores, pero es necesario prueba específica.
(3) Tablero estándar sin medidas adicionales de EMC. Puédese atender categoría C1 adicionando
accesorios EMC en el tablero. En este caso débese realizar prueba específica para verificar niveles de
emisión.
(4) Para temperatura alrededor del convertidor y filtro de 45 °C y corriente de salida continua mayor que
172 Arms, es necesario usar el filtro B84143B0250S020.
(5) Para temperatura alrededor del convertidor y filtro de 40 °C y aplicaciones con régimen de sobrecarga
pesada (HD, corriente de salida < 180 Arms), es posible usar el filtro B84143B0180S020.
(6) Es necesario usar el armario metálico y usar un toroide Würth Elektronik WE74270191 por fase en la
entrada del convertidor de frecuencia.
Notas:
(1) Os filtros RFI externos apresentados na tabela B.6 foram escolhidos com base na corrente de entrada
nominal do inversor especificada para aplicação ND (regime de sobrecarga normal) e temperatura
ambiente ao redor do inversor de 50 °C. Para otimizar, considerar a corrente de entrada do inversor e a
temperatura ambiente ao redor do inversor na aplicação para definir a corrente nominal do filtro RFI externo
a ser utilizado. Para mais informações consultar a EPCOS.
(2) É possível utilizar comprimentos maiores, porém é necessário teste específico.
(3) Painel padrão sem medidas adicionais de EMC. Pode-se atender categoria C1 adicionando-se
acessórios EMC no painel. Nesse caso deve-se realizar teste específico para verificar níveis de emissão.
(4) Para temperatura ao redor do inversor e filtro de 45 °C e corrente de saída contínua maior que 172
Arms, é necessário usar o filtro B84143B0250S020.
(5) Para temperatura ao redor do inversor e filtro de 40 °C e aplicações com regime de sobrecarga pesada
(HD, corrente de saída < 180 Arms), é possível usar o filtro B84143B0180S020.
(6) É necessário usar painel metálico e usar um toróide Würth Elektronik WE74270191 por fase na entrada
do inversor.
CFW700 | 187