After setting the "Neutral Measurement" factor, store with the Print
button, Position 01 is displayed.
Press the Zero button,   appears on the display.
To save the setting and exit, press and hold the Print button then
briefly press the Zero button. The display returns to weighing mode.
Neutral measurement application
Activate the "Neutral Measurement" function with the Function key.
The display shows  for "Neutral Measurement", confirm with
the Print button.
The display value appears along with the selected factor without a unit
weight. Stabilisation of the scales is represented on the display by a
triangle at the top left.
Press the ON/Off button to return to weighing mode.
Weighing toddlers
An adult steps or stands onto the scales.
> The display could show »67.6 kg« for example
Press the TARA key.
> The display changes to »0.0 kg«
The adult steps off the scales ...
> Display »–67.6 kg«
...then steps or stands on the scales again holding the child.
> The display now indicates the child's weight, for example »5.1 kg«
Zero setting
Press the Zero button to correct any minor deviations from the zero
point, which may be caused by dirt on the scales.
Verifiable and non-verifiable zero setting range: -1 to +3% of the
weighing range.
Turning off / Safely end use
Press the ON/OFF button to switch off the scales.