Filling The Solution Tank; Squeegee Installation - Clarke FOCUS II LARGE Serie Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FILLING THE SOLUTION TANK

Fill the solution tank with a maximum of 30 gallons (113.5 Liters) of cleaning solution. Do not fi ll the solution tank above 7.5 cm (3 inches) from the
bottom of the Solution Fill (1). The solution should be a mixture of water and the proper cleaning chemical for the job. Always follow the dilution
instructions on the chemical container label. NOTE: EcoFlex machines can either be used conventionally with detergent mixed in the tank or the
detergent dispensing system can be used. When using the detergent dispensing do not mix detergent in the tank, plain water should be used.
CAUTION!
Use only low-foaming, non-fl ammable liquid detergents intended for machine application. Water temperature should not exceed 130
degrees fahrenheit (54.4 degrees celsius)

SQUEEGEE INSTALLATION

1
See Figure 3. Slide the Squeegee Assembly (13) onto the squeegee mount bracket and tighten the Squeegee Mount Thumb Nuts (25).
2
Connect the Recovery Hose (19) to the squeegee inlet.
3
Lower the squeegee, move the machine ahead slightly and adjust the squeegee tilt using the Squeegee Adjustment Knob (26) so that the
rear squeegee blade touches the fl oor evenly across its entire width and is bent over slightly as shown.
FIGURE 3
FORM NO. - 56091028 - FOCUS
ENGLISH / A-11
II LARGE - A-11
®

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

5638182556381828

Tabla de contenido