Problem
Restricted air flow or no air
flow
Filter warning light is on
The turbine has no power
Excessive arcing/sparking in
the turbine
These products are covered by one or more of the following U.S. patents:
5,423,395
D365,569
5,772,711
© 1999 Wagner Spray Tech Corporation. All rights reserved.
Page 5

Troubleshooting

Cause
1. Air flow adjustment knob on the spray
gun is turned off
2. Air filters are clogged
1. Air filters are clogged
1. No power at the power supply
2. The fuse is blown
3. Worn turbine brushes
1. Worn turbine brushes
2. Damaged commutator
Patents
D322,790
5,181,832
5,556,255
5,639,222
Solution
1. Adjust the air flow adjustment knob
2. Clean or replace the filters
1. Clean or replace the filters
1. Check the power supply
2. Check and replace the fuse
3. Have the brushes replaced at an authorized
Wagner service center
1. Have the brushes replaced at an authorized
Wagner service center
2. Replace the turbine (contact a Wagner
service technician)
D338,208
5,174,610
5,702,131
5,558,492