Specifications - Tanita TBF-300A Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2. Specifications

MODEL
TBF-300A
Measurement System
Measurement Frequency
Impedance
Measurement Current
Measurement
Electrode Material
Measurement Style
Measurement Range
Measurement System
Weight
Maximum
Minimum
/
Measurement
Capacity
Graduation
Clothes Weight
Gender
Body Type
Input Items
Age
Height
Target Body Fat %
Target Body Fat %
Weight
Gender
Age
Display
Height
Body Type
Height
FAT%
Body Type
Gender
Age
Output Items
Height
Weight
BMI
Print out
BMR
Impedance
FAT%
Fat Mass
FFM
TBW
Wrestler section information
Others
Desirable Range for FAT% and FM
(Standard and 20~79 years old ONLY)
Display
Cable Length Between Weighing Platform
and Control Box
Output Data Interface
Power Source
Rated Power
Power Consumption
Temperature Range of usage
Weight of
Weighing Platform
Equipment
Control Box
4
TBF-300
TBF-310
Tetrapolar Bioelectrical Impedance Analysis
50kHz
500µA
Pressure Contact Stainless Steel Foot Pads
Between Both Feet
150 ~ 900Ω
Strain Gauge Load Cell
200kg / 0.1kg
270kg / 0.2kg
440lb / 0.2lb
600lb / 0.5lb
0~200kg / 0.1kg increments
0 ~ 270kg / 0.2kg increments
0~440lb / 0.2lb increments
0 ~ 600lb / 0.5lb increments
Male / Female
Standard / Athletic
7 ~ 99 years old / 1year increments
90 ~ 249cm / 1cm increments
3ft ~ 7ft 11.5in / 0.5in increments
4 ~ 55%
4 ~ 55%
0 ~ 200kg / 0.1kg increments
0 ~ 270kg / 0.2kg increments
0 ~ 440lb / 0.2lb increments
0 ~ 600lb / 0.5lb increments
Male / Female
7~99 years old / 1year increments
90 ~ 249cm / 1cm increments
3ft ~ 7ft 11.5in / 0.5in increments
Standard / Athletic
90 ~ 249cm / 1cm increments
1 ~ 75% / 0.1% increments
Standard / Athletic
Male / Female
7 ~ 99 years old / 1year increments
90 ~ 249cm / 1cm increments
3ft ~ 7ft 11.5in /0.5in increments
2 ~ 200kg / 0.1kg increments
4 ~ 270kg / 0.2kg increments
4.4 ~ 440lb / 0.2lb increments
10 ~ 600lb / 0.5lb increments
0.1 increments
1kJ increments / 1kcal increments
150 ~ 900Ω / 1Ω increments
1 ~ 75% / 0.1% increments
0.1kg / 0.2lb increments
0.2kg / 0.5lb increments
Desirable Range for FAT% and FM
(Standard and 20~79 years old ONLY)
3 Rows, 5Digits LCD
2m / 6ft6.5in (Remote Type)
RS-232C (D-sub 9 pins Male Connector)
AC Adapter (included) Center Minus
DC5V 3.5A
17.5W
0 ~ 35ºC / 32 ~ 95ºF
7.0kg / 15.4lb
5.4kg / 11.9lb
1.0kg / 2.2lb
MODEL
Measurement System
Measurement Frequency
Impedance
Measurement Current
Measurement
Electrode Material
Measurement Style
Measurement Range
Measurement System
Weight
Maximum
Minimum
/
Measurement
Capacity
Graduation
Clothes Weight
Gender
Body Type
Input Items
Age
Height
Target Body Fat %
Target Body Fat %
Weight
Gender
Age
Display
Height
Body Type
Height
FAT%
Body Type
Gender
Output Items
Age
Height
Print out
Weight
with
Printer
BMI
Model
BMR
ONLY
Impedance
FAT%
Fat Mass
FFM
TBW
Others
Desirable Range for FAT% and FM (Standard and 20 ~ 79 years old ONLY)
Display
Output Data Interface
Power Source
Rated Power
Power Consumption
Temperature Range of usage
Weight of Equipment
TBF-410
Tetrapolar Bioelectrical Impedance Analysis
50kHz
500µA
Pressure Contact Stainless Steel Foot Pads
Between Both Feet
150 ~ 900Ω
Strain Gauge Load Cell
200kg / 0.1kg
440lb / 0.2lb
0 ~ 200kg / 0.1kg increments
0 ~ 440lb / 0.2lb increments
Male / Female
Standard / Athletic
7 ~ 99 years old / 1year increments
90 ~ 249cm / 1cm increments
3ft ~ 7ft 11.5in / 0.5in increments
4 ~ 55%
4 ~ 55%
0 ~ 200kg / 0.1kg increments
0 ~ 440lb / 0.2lb increments
Male / Female
7~99 years old / 1year increments
90 ~ 249cm / 1cm increments
3ft ~ 7ft 11.5in / 0.5in increments
Standard / Athletic
90 ~ 249cm / 1cm increments
1 ~ 75% / 0.1% increments
Standard / Athletic
Male / Female
7~99 years old / 1year increments
90 ~ 249cm / 1cm increments
3ft ~ 7ft 11.5in / 0.5in increments
2 ~ 200kg / 0.1kg increments
4.4 ~ 440lb / 0.2lb increments
0.1 increments
1kJ increments / 1kcal increments
150 ~ 900Ω / 1Ω increments
1 ~ 75% / 0.1% increments
0.1kg / 0.2lb increments
3 Rows, 5Digits LCD
RS-232C (D-sub 9 pins Male Connector)
AC Adapter (included) Center Minus
DC5V 3.5A
17.5W
0 ~ 35ºC / 32 ~ 95ºF
11.0kg / 24.2lb
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tbf-300Tbf-310Tbf-410

Tabla de contenido