- EN -
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Attention! Never operate the unit with a water pressure of more than 0.2 bar!
How to proceed:
C
Important:
Switch the pump on first, then the UVC clarifying unit.
Do not operate the unit without water flowing through.
The unit switches on automatically when power connection is established.
Switching on: Connect power plug to the socket.
The control lamp is lit.
Note:
After a new installation, the unit only reaches its full biological cleaning effect after a few weeks.
The full effect on bacteria is only reached as from a water temperature of + 10 °C.
In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Check all connections for leaks.
Switching off: Disconnect the power plug.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Note:
Check and clean the water outlet into the pond at regular intervals.
Clean the filters at regular intervals (e.g. every four weeks), however, at the latest when cloudy or dirty water from
the water outlet returns to the garden pond.
Carry out quick cleaning first. Should this prove insufficient, clean the entire unit.
A blocked filter could lead to leakages.
Never use chemical cleaning agents.
Quick cleaning
How to proceed:
D
Switch off the filter pump.
Remove hose from the filter outlet by turning off the union nut (1).
Remove hose from the filter inlet by turning off the union nut and screw on the filter outlet (2).
Screw a dirt drain hose with stepped hose adapter on the filter inlet.
Switch on the filter pump.
Vigorously pull on the cleaning handle and „pump" several times (3). In this manner, the foam filters are mechani-
cally cleaned until the draining water is clear.
Switch off the filter pump.
Remove the dirt drain hose and correctly reconnect the hoses for normal operation (Figure A).