Safety notes

Example safety note:
Electrical hazard!
Comply with the safety instructions!
Before using the BENNING MM 4 read the operating instructions carefully.
Always comply with the safety notes given in the operating instructions. This is
essential in order to avoid accidents and damage to the BENNING MM 4.
3.

Scope of supply

The following items make up the standard BENNING MM 4 package:
3.1 one Multimeter,
3.2 one current transducer clamp,
3.3 one safety test lead, black (length = 1.4 m, tip Ø 4 mm) with safety
caps,
3.4 two test probes, red (tip Ø 4 mm),
3.5 one insulated crocodile clamp,
3.6 one compact protection case,
3.7 two 1.5 V micro-batteries (in place in Multimeter on delivery),
3.8 the set Operating Instructions.
Note on consumable parts:
The BENNING MM 4 is supplied by two 1.5 V batteries (2 x 1,5-V-IEC LR 03).
4.

Description of unit

The BENNING MM 4 consists of two functional units:
-
the Multimeter and
-
the current transducer clamp.
See fig.1:
The operating and indicating elements shown in fig. 1 are as follows:
1 Housing
2 Sliding switch for selecting the desired functions.
-
Aus (OFF)
-
Measurement of alternating voltage (AC) and direct voltage (DC).
These functions alternate with one-another when the function button
with the blue marking is pressed. When pressed longer (2 sec.) meas-
urement of alternating current, etc. The digital display 3 indicates the
function currently in effect.
-
Resistance measurement, continuity test with buzzer and diode
test. These functions alternate with one-another when the function
button with the blue marking is pressed. The digital display 3 indicates
the function currently in effect.
3 Digital display (liquid-crystal principle). The following are indicated:
-
the measurement value with the max. indication 4200,
-
the polarity indication,
-
the decimal point,
-
the symbol for discharged battery,
-
the type of voltage selected (DC or AC voltage),
-
the measurement value held (hold function),
-
the deviation from a measurement value stored in the unit memory
(REL ∆),
-
the selected measuring range through display of extended / non-
extended measuring units of voltage, current and resistance,
-
the selected continuity test with buzzer,
-
the selected diode test.
4 Blue function button: the following symbols appear for this in the digital
display 3: "DC"; "AC"; "Ω", "V"; „
-
Selection between DC-voltage and AC-voltage measurement or
-
resistance measurement, continuity and diode test,
-
or when button pressed for 2 sec. (in sliding-switch position ACV / DCV)
alternating current (Amp).
-
Measurement of temperature (°C, °F), relative humidity (%), capacity
(µF), carbon monoxide (ppm), wind speed (m/s), illumination intensity
(k lux) are not possible with the BENNING MM 4.
-
Repeat press for 2 sec. returns to voltage measurement
5 HOLD / REL button (hold function)
-
First press of button causes indicated measuring value to be held (indi-
cated by 'Hold' in digital display 3, no updating of measured value),
-
repeat press of button causes return to continuous measurement function.
-
Relative-value function becomes effective when button pressed for 2
sec. The value currently being measured is stored and the difference
11/ 2008
Front panel of unit
BENNING MM 4
" or „
"
10