Maintenance
Always test for leaks after servicing and/or replacing parts.

Cleaning and disinfection

Before cleaning, remove any accessories from the mask and clean
1)
them separately
.
The mask must be cleaned and disinfected each time it is used.
WARNING
The mask body must be cleaned sufficiently thoroughly that no
residues from skin care products remain on it.
Otherwise the elasticity in the sealing area can be lost and the mask
will no longer sit correctly.
If this warning is not heeded, poisoning or death can result.
CAUTION
Do not use solvents such as acetone, alcohol or similar for cleaning.
Use only the cleaning agents and disinfectants listed below.
Excessive dosing and overlong exposure times that deviate from the
specifications described here or from the specifications of the
manufacturer of the cleaning and disinfection agent, can cause
damage to the full face mask, e. g. the visor can become brittle
Do not use a cloth to clean or dry the inside of full face masks with
visors that are marked "PC/CC", as the coating can be damaged as
a result. After drying, these masks should be aired unpacked for at
least one day under standard climatic conditions according to
DIN EN ISO 291, so that the coating can regenerate and the
optimum working life is achieved.
1)
Note the corresponding Instructions for Use.
12
Clean and disinfect the full face mask as follows:
Clean the full face mask using water (max. 30 °C) with a universal
cleaning agent, Sekusept Cleaner
Immediately afterwards, remove the cleaning agent completely
under running water.
Immerse the full face mask for 15 minutes in the disinfectant bath
®1)
(max. 30 °C) with Incidur
Immediately afterwards, remove the disinfectant completely under
running water.
Leave the mask to dry completely in a drying cabinet or in the
open air. Temperature max. 60 °C. Do not expose to direct
sunlight.
Testing
Test the mask in accordance with the test and maintenance intervals.
Test and maintenance intervals
The following details are recommendations based on the BGR 190
applicable in Germany. Observe your own national guidelines.
Work required on full-face
mask
Check by the wearer
Visually inspect, check correct
function and leak-proofing
Cleaning and disinfection
Replace exhalation valve disc
Replace speech diaphragm
1)
For airtight packed masks, every 2 years.
2)
For airtight packed masks, otherwise every 6 months.
®1)
(0.5-1.0 % solution).
disinfectant (2 % solution).
X
X
1)
X
X
2)
X
X
X