Description
3.1
Product overview
3.2
Intended use
The product described is a cordless (battery-powered) electro-hydraulic cutting tool.
It is designed for cutting through cables made of copper (Cu) or aluminum (Al).
Before use of the power tool, all live cables or other items carrying electric voltage within the area in which
the user is working must be switched off. If this is not possible, the corresponding safety precautions for
working in the proximity of live cables or equipment must be implemented and observed.
Use only Hilti lithium­ion batteries of the B 22 series with this product.
Use only Hilti-approved battery chargers to charge these batteries. More information is available from
your Hilti Store or from www.hilti.group
3.3

Possible misuse

Do not use this hand-held product clamped in a fixed position or as a stationary device.
Do not use the product in heavy rain or under water.
Do not use the product for cutting steel.
3.4
Lithium­ion battery status display
The charge state of the Li-ion battery and malfunctions of the product are indicated by the indicator of the
Li­ion battery. The charge status of the Li­ion battery is indicated after one of the two battery release buttons
is short-pressed.
Status
4 LEDs light.
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED flashes.
Battery state of charge cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch. If the LEDs of the charge state indicator flash, follow the instructions
in the 'Troubleshooting' section.
3.5
Items supplied
Cutting tool, operating instructions.
Other system products approved for use with this product can be found at your local HILTI STORE or online
at: www.hilti.group
14
English
1
Cutting edge
@
Cutting head
;
Key ring
=
Casing
%
Servicing and fault indicator (red LED)
&
Manual piston return switch
(
Control switch
)
Battery release button
+
Battery
§
Grip (optional), possible installed position
/
White LED to illuminate the working area
:
Meaning
State of charge: 75 % to 100 %
State of charge: 50 % to 75 %
State of charge: 25 % to 50 %
State of charge: 10 % to 25 %
State of charge: < 10 %