Laser class
Beam diameter
Self-leveling range
Automatic power-off
Operating status indicator
Power supply
Battery life
Operating temperature range
Storage temperature
Dust and water spray protection (except battery com-
partment)
Tripod thread (tool)
Tripod thread (foot)
Weight
Dimensions
1 Influences such as particularly high temperature fluctuations, dampness, shock, dropping, etc. can affect accuracy. Unless stated
otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810F).

5 Safety instructions

In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.

5.1 General safety rules

a) Check the accuracy of the tool before using it to
take measurements.
b) The tool and its ancillary equipment may present
hazards when used incorrectly by untrained per-
sonnel or when used not as directed.
c) To avoid the risk of injury, use only genuine Hilti
accessories and additional equipment.
d) Modification of the tool is not permissible.
e) Observe the information printed in the operat-
ing instructions concerning operation, care and
maintenance.
Do not render safety devices ineffective and do
f)
not remove information and warning notices.
g) Keep laser tools out of reach of children.
h) Take the influences of the surrounding area into
account. Do not expose the tool to rain or snow
and do not use it in damp or wet conditions. Do
not use the tool where there is a risk of fire or
explosion.
i)
Check the condition of the tool before use. If the
tool is found to be damaged, have it repaired at a
Hilti service center.
Class 2, visible, 620 - 690 nm, ±10 nm (EN 60825-
3:2007 / IEC 60825 - 3:2007); class II (CFR 21 §1040
(FDA)
Distance 5 m: < 4 mm
Distance 20 m: < 16 mm
±5° (typical)
Activated after: 15 min
LED and laser beams
AA‑size batteries, Alkaline batteries: 4
Alkaline battery 2,500 mAh, Temperature +25°C
(+77°F): 30 h (Typical)
Min. -10°C / Max. +50°C (+14 to 122°F)
Min. -25°C / Max. +63°C (-13 to 145°F)
IP 54 as per IEC 529
UNC¹⁄₄"
BSW ⁵/₈" UNC ¹/₄"
With foot but without batteries: 0.413 kg ( 0.911 lbs)
With foot: 140 mm X 73 mm X 107 mm
Without foot: 96 mm X 65 mm X 107 mm
j)
The user must check the accuracy of the tool
after it has been dropped or subjected to other
mechanical stresses.
k) When the tool is brought into a warm environment
from very cold conditions, or vice-versa, allow it
to become acclimatized before use.
l)
If mounting on an adapter, check that the tool is
screwed on securely.
m) Keep the laser exit aperture clean to avoid meas-
urement errors.
n) Although the tool is designed for the tough condi-
tions of jobsite use, as with other optical and elec-
tronic instruments (e.g. binoculars, spectacles,
cameras) it should be treated with care.
o) Although the tool is protected to prevent entry
of dampness, it should be wiped dry each time
before being put away in its transport container.
p) Check the accuracy of the measurements several
times during use of the tool.

5.2 Proper organization of the work area

a) Secure the area in which you are working and
take care to avoid directing the beam towards
other persons or towards yourself when setting
up the tool.
b) Avoid unfavorable body positions when working
from ladders. Make sure you work from a safe
stance and stay in balance at all times.
en
13

Publicidad

Tabla de contenido
loading

Tabla de contenido