Self-leveling range
Automatic power-off
Operating status indicator
Power supply
Battery life (2 points and 1 line)
Operating temperature range
Storage temperature
Dust and water spray protection (except battery
compartment)
Tripod thread
Weight
Dimensions

5. Safety instructions

In addition to the information relevant to safety
given in each of the sections of these operating
instructions, the following points must be strictly
observed at all times.

5.1 General safety rules

a) Check the accuracy of the tool before using it to
take measurements.
b) The tool and its ancillary equipment may
present hazards when used incorrectly by
untrained personnel or when used not as
directed.
c) To avoid the risk of injury, use only genuine
Hilti accessories and additional equipment.
d) Do not open the casing of the tool.
e) Modification of the tool is not permissible.
f) Observe the information printed in the operat-
ing instructions concerning operation, care and
maintenance.
g) Do not render safety devices ineffective and do
not remove information and warning notices.
h) Keep laser tools out of reach of children.
i) Failure to follow the correct procedures when
opening the tool may cause emission of laser
radiation in excess of Class 3R / Class IIIa. Have
the tool repaired only at a Hilti service center.
j) Take the influences of the surrounding area into
account. Do not expose the tool to rain or snow
and do not use it in damp or wet conditions. Do
Printed: 07.07.2013 | Doc-Nr: PUB / 5071411 / 000 / 00
±3.5°
Activated after: 15 min
LED and laser beams
AA size batteries, Alkaline batteries: 4
Alkaline battery 2,500 mAh, Temperature +25°C
(+77°F): 40 h
Min. -10°C / Max. +50°C (+14 to 122°F)
Min. -20°C / Max. +63°C (-4 to 145°F)
IP 54
IEC 529
BSW "UNC "
Without batteries: 0.66 kg
Foot in the closed position: 138 mm X 51 mm X
89 mm
Foot in the open position: 164 mm X 51 mm X
126 mm
not use the tool where there is a risk of fire or
explosion.
k) Check the condition of the tool before use. If the
tool is found to be damaged, have it repaired at
a Hilti service center.
l) The user must check the accuracy of the tool
after it has been dropped or subjected to other
mechanical stresses.
m) When the tool is brought into a warm environ-
ment from very cold conditions, or vice-versa,
allow it to become acclimatized before use.
n) If mounting on an adapter, check that the tool
is screwed on securely.
o) Keep the laser exit aperture clean to avoid
measurement errors.
p) Although the tool is designed for the tough con-
ditions of jobsite use, as with other optical and
electronic instruments (e.g. binoculars, spec-
tacles, cameras) it should be treated with care.
q) Although the tool is protected to prevent entry
of dampness, it should be wiped dry each time
before being put away in its transport container.
r) Check the tool before using it for important
measuring work.
s) Check the accuracy of the measurements sev-
eral times during use of the tool.
en