Dimensions (L × W × H)
Weight (including batteries)
Power source
Battery life
Operating temperature range
en
Storage temperature range
Protection class
Drop test height
1
1 The drop test was carried out using the PRA 83 receiver holder, dropped onto flat concrete under standard ambient conditions
(MIL-STD-810G).
PRA 84 Li‑ion battery
Rated voltage (normal mode)
Maximum voltage (during operation or during charging
while in operation)
Rated current
Charging time
Operating temperature range
Storage temperature range (dry)
Charging temperature range (also for charging during
operation)
Weight
Dimensions (L x W x H)
PUA 81 AC adapter
AC supply
AC frequency
Rated power
Rated voltage
Operating temperature range
Storage temperature range (dry)
Weight
Dimensions (L x W x H)

5 Safety instructions

5.1 Basic information concerning safety

In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
20
160 mm × 67 mm × 24 mm
0.25 kg
2 AA batteries
Temperature +20°C: Approx. 50 h (depending on the
quality of the alkaline batteries used)
-20...+50°C
-25...+60°C
IP 66 (in accordance with IEC 60529); Except the bat-
tery compartment
2 m
7.2 V
13 V
140 mA
Temperature +32°C: 2 h 10 min (battery 80% charged)
-20...+50°C
-25...+60°C
+0...+40°C
0.3 kg
160 mm x 45 mm x 36 mm
115...230 V
47...63 Hz
36 W
12 V
+0...+40°C
-25...+60°C
0.23 kg
110 mm x 50 mm x 32 mm

5.2 General safety rules