Maytag MED5591TQ1 Manual De Uso página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Alternate
installations
for
close clearances
Venting
systems come
ill many varieties.
Select the type best for your installation.
Two close-
clearance
installations
are shown.
Refer to the manufacturer's
instructions.
A
B
A. Over-the-top installation (aho available with one offset elbow)
B. P_'riscope installation
NOTE: The following
kits for close clearance
alternate
installations
are available
for purchase.
Please see the "Assistance
or Service"
section
to order.
Over-the-Top
Installation:
Part Number
4_96028
Periscope
Installation
(For use with
dryer vent to wall vent mismatch/:
Part Number
4396037
- 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number
4396011
- 18" (45.72
cm) to 29" (73.66
cm) mismatch
Part Number
4396014
- 29" (73.66
cm) to 50" (127 cm) mismatch
Special provisions
for mobile
home installations
lhe
exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath the mobile
home.
|erminate
the exhaust
vent
outside.
S
Determine
vent path
Select the route that will provide
the straightest
and most direct
path outdoors,
Plan the installation
to use the fewest
number
of elbows
and turns.
When
using elbows
or making
turns,
allow as much
room as possible.
Bend vent gradually
to avoid kinking.
Use the fewest 90 ° turns possible.
Determine
vent length
and elbows
needed
for best drying
performance
Use the Vent system chart below
to determine
type of vent material
and hood
combinations
acceptable
to use.
NOTE:
Do not use vent runs longer than those specified
in the Vent system chart.
Exhaust
systems longer than those specified
will:
Shorten
the life of the dryer.
Reduce performance,
resuhing
in longer drying
times and increased
energy
usage.
[he Vent system chart provides
venting
requirements
that will
help to achieve
the best drying
performance.
Vent
systems
charts
When
using only one type of metal vent:
Use the following
chart to help you determine
your maximum
vent length based on the
number
_1"90 _' turu_ ur elb_w_
yuu will need and ttl_ type ul veuL (ri:4id arld/ur
flexibl_,
metal) you will
use.
Vent system
chart
..............................................................................................................................................................................................................................
Number
of 90 °
Rigid metal vent
Flexible metal vent
turns or elbows
0
120 ft (36.6 m)
40 ft (12.2 m)
..... i......................................................
ii0iiZ- Tmi.................................. .....................................
..............................................................................................................................................................................................................................
2
100 ft Iq0.5
m)
3% ft (10.1 m)
..............................................................................................................................................................................................................................
3
90 ft (27.4 m)
30 ft (9.1 m/
..............................................................................................................................................................................................................................
4
80 ft (24.4 m)
27 ft (8.2 m)
..............................................................................................................................................................................................................................
5
70 ft (21.3 m)
23 ft (7.0 m)
When
using a combination
of rigid and flexible metal vent:
Use the following
charts to help you determine
your maximum
vent length based on the
number
of 90 ° turns or elbows
you will need.
Determine
the number
of elbows
or turns you will
need.
Determine
the length of the fully
extended
flexible
metal vent you will
use. Find the
column
that has the nearest number
of feet to what you will
be using.
Match the number
of turns or elbows
with
the length of the fully
extended
flexible
metal vent you will
use to find the maximum
length of rigid metal vent you can use,
16