Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical
connections.
Failure to de so can result in death, fire, or
electrical shock.
Direct
Wire
Fire Hazard
Use 10 gauge solid copper
wire.
Use a UL listed strain
relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1.
Disconnect
power.
2.
Remove the hold-down
screw
and terminal
block
cover.
A
B
C
D
......
E
F
A. 7_'rminal
block
cov_'r
B. [-xternal
ground
conductor
sL r_'vV
C. O_nt_'l; silver-color_'d
t_'rminal
block screw
D. Hold-down scr_'wlocation
E. Neutral
ground
wire
F. Hole below
tem'linal
block
opening
Style 1: Power supply
cord strain relief
Remove the screws from a ¾" (1.9 cm) U[. listed strain relief (UL marking
on strain
relief).
Put the tabs of the two clamp
sections
into the hole below
the terminal
block
opening
so that one tab is pointing
up and the other is pointing
down,
and hold in
place. Tighten strain relief screws just enough
to hold the two clamp sections together.
A. Strain relief
tab pointing
LIp
B. Hole
below
t_'rminal
block
opening
C. Clamp
section
D. Strain relief
tab pointing
down
3.
Install strain relief.
8