Primary And Hepa Filter Disassembly And Replacement; Primary Star Filter Replacement; Primary Cartridge Filter Replacement - Nilfisk cfm T26 Plus Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

T26 Plus - T48 Plus - T63 Plus
Primary and HEPA filter disassembly and
replacement
When the vacuum cleaner is used to vacuum
hazardous substances, the filters become
contaminated, therefore:
■ Work with care and avoid spilling the vacuumed
dust and/or material;
■ Place the disassembled and/or replaced filter in a
sealed plastic bag;
■ Close the bag hermetically;
■ Dispose of the filter in accordance with the laws in
force.
Filter replacement is a serious matter. The filter must
be replaced with one of identical characteristics,
filtering surface and category.
Otherwise the vacuum cleaner will not operate
correctly.

Primary star filter replacement

1.
Vacuum hose
2.
Release lever
3.
Cover
4.
Clamp
Take care not to raise dust when this operation is carried out.
Wear a P3 mask and other protective clothing plus protective
gloves (DPI) suited to the hazardous nature of the dust
collected, refer to the laws in force.
Before proceeding with these operations, turn off the vacuum
cleaner and remove the plug from the power socket.
Loosen the clamp (4).
Remove the vacuum hose (1).
Use the lever (2) to remove the cover (3) together with
the primary filter.
Remove the old filter from the cage.
Fit the new filter and secure it in the cage with special
US
ties.
Install the cover and the primary filter in the reverse order
of removal.
Dispose of the old filter according to the laws in force.
If necessary contact the manufacturer's Service Centre.
C386
WARNING!
WARNING!
Figure 12

Primary cartridge filter replacement

1.
Vacuum hose
2.
Clamp
3.
Cap
4.
Release lever
5.
Filter ring
6.
Cartridge assembly
7.
Power supply cable
8.
Air intake coupling
9.
Junction
10. Connector
11. Screws
12. Screws
13. Washer
14. Cartridges
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
Before performing these procedures, turn off the machine
and remove the plug from the power socket, disconnect the
compressed air supply by emptying the air tank inside the
machine.
Loosen the clamp (2).
Remove the vacuum hose (1).
Operate the levers (4).
Remove the cover (3) and the filter ring (5).
Disconnect the power supply cable (7) and the
compressed air supply from the air intake coupling (8).
Remove the cartridge assembly (6).
Disconnect the connectors (10) and the union (9).
Disassemble the air tank by operating on the screws
(11).
Disassemble the cartridges by operating on the screws
(12) and washers (13).
Assemble the new cartridges.
Install the cartridge assembly in the in the reverse order
of removal.
Dispose of the old filters according to the laws in force.
If necessary contact the manufacturer's Service Centre.