T26 Plus - T48 Plus - T63 Plus

Device disposal

Dispose of the device in compliance with the laws in force.
Proper disposal (electric and electronic waste).
(Applicable in the countries providing a separate
collection system)
The above symbol (Fig. 18), which is present on the product
or in its documentation, indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damage to the environment or health caused by
improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reutilisation of material resources.
This product can not be disposed of together with other
commercial waste.
US
C386
Figure 18

Wiring diagrams

Item
Type
Description
H1
40000563
White indicator kit
H3
40000564
Yellow indicator kit
Z8 39281
Contactor kW4 24VAC 1NO
Z8 391005 +
Contactor kW5.5 24VAC 1NO
KM1
Z8 39838
Z8 39102 +
Contactor kW11 24VAC 1NO
Z8 39838
PA
40000565
Stop button kit (red)
PM
40000562
Start button kit (green)
Z8 39915 +
5.5-8A circuit breaker
Z8 39924
Z8 39916 +
9-12.5A circuit breaker
Z8 39924
Q1
Z8 39014 +
11-16A circuit breaker
Z8 39924
Z8 39675 +
25-32A circuit breaker
Z8 39687
QF1
4083901368 0.3A 2P circuit breaker
QF2
4083901496 1A 1P circuit breaker
SF1
4083901490 Phase sequence relay 208/480 V
TR1
4083901491 Transformer 20 VA 208/230/460/24 V

Timing for cartridge filter clearing

1.
Timer
2.
Filter cleaning solenoid valve 1
3.
Filter cleaning solenoid valve 2
4.
Filter cleaning solenoid valve 3
5.
Filter cleaning solenoid valve 4 (presetting)
T1 = Filter cleaning time factory setting 0.25
T2 = Time between two filters factory setting 30 s
T3 = Time between cleaning cycles factory setting 60 s
T1 (40ms ÷ 1 sec)
During T1 a red led for each ouput lights on.
T2 (1 ÷ 60 sec)
During T2 the green led lights on.
T3 (1 ÷ 60 sec)
During T3 the yellow led lights on.
12
Figure 19
Figure 20
02/2013
Q.ty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T48 plusT63 plus

Tabla de contenido