5 Installation
5.2.1
Mounting the main housing in a concrete pool
Ensure that the top outlet connection is positioned above the inlet
connection. Determining the mounting depth: The middle of the main
housing / nozzles should lie 30 cm under the water level. Insert the nub
seal (26) in the housing (1), align the main housing and fasten to the
formwork with 4 tapping screws. Press the sealing round cord into the
housing groove. Please observe the installation sketch. The dummy
plate (30) is used to protect the housing during plastering and as a
cover in the case of commissioning the swimming pool without the final
assembly kit being installed. ATTENTION: Do not use any force when
tightening the screws.
Installation suggestion for concrete pools
1) Fastening to the formwork (4x)
62 EN
VG 766.2320.050
1)
1)
1)
1)
Ø7
Fig. 1
12/2014