Cleaning Of The Spray Gun - SATA SATAjet 3000 K RP Instrucciones De Servicio

Ocultar thumbs Ver también para SATAjet 3000 K RP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 109
Operating Instructions SATAjet 3000 K RP/HVLP
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.
8.

Cleaning of the Spray Gun

• Prior to cleaning, please disconnect the paint spray gun from the
compressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty spray gun completely, dispose of paint material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, alkalines, bases, pickling agents, unsuit-
able regenerates or other aggressive cleaning solutions!*
• Do not soak paint spray gun in cleaning solution!*
• Drillings should be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to be put under pressure with clean compressed
air during the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the gun washing machine imme-
diately after the cleaning process!*
• Never use ultrasonic cleaning devices - leads to damage of
nozzle set and gun surface!
• After cleaning, the spray gun, the material passages, the air
cap including thread have to be blown dry with clean com-
pressed air!*
* otherwise risk of corrosion
Danger! Notice!
US
399

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Satajet 3000 k hvlp

Tabla de contenido