Rockwell Automation Allen-Bradley PowerFlex 40P Serie Guia De Inicio Rapido página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
Category
Specification
Agency
Certification
. .
TUV
Rheinland
Product Safety
Production inspected
The drive is also designed to meet the appropriate portions of the following specifications:
NFPA 70 - US National Electrical Code
NEMA ICS 3.1 - Safety standards for Construction and Guide for Selection, Installation and
Operation of Adjustable Speed Drive Systems.
IEC 146 - International Electrical Code.
Bus Overvoltage Trip
Protection
200-240V AC Input:
380-460V AC Input:
460-600V AC Input:
Bus Undervoltage Trip
200-240V AC Input:
380-480V AC Input:
460-600V AC Input
P042 = 3 "High Voltage":
P042 = 2 "Low Voltage":
Power Ride-Thru:
Logic Control Ride-Thru:
Electronic Motor Overload Protection:
Overcurrent:
Ground Fault Trip:
Short Circuit Trip:
Altitude:
Environment
Maximum Surrounding Air Temperature
without derating:
IP20, Open Type:
IP30, NEMA Type 1, UL Type 1:
Flange and Plate Mount:
Cooling Method
Convection:
Fan:
Storage Temperature:
Atmosphere:
Relative Humidity:
Shock (operating):
Vibration (operating):
Voltage Tolerance:
Electrical
Frequency Tolerance:
Input Phases:
Displacement Power Factor:
Maximum Short Circuit Rating:
Actual Short Circuit Rating:
Transistor Type:
Listed to UL508C and CAN/CSA-22.2
U L
®
C
US
Certified to AS/NZS, 1997 Group 1, Class A
Marked for all applicable European Directives
EMC Directive (89/336)
EN 61800-3, EN 50081-1, EN 50082-2
Low Voltage Directive (73/23/EEC)
EN 50178, EN 60204
Certified to EN 954-1, Category 3.
Bauart geprüft
Functional
Meets Functional Safety (FS) when used with the
. .
EN 50178
TUV
Safety
Rheinland
DriveGuard Safe-Off Option (Series B).
Type approved
405V DC bus (equivalent to 290V AC incoming line)
810V DC bus (equivalent to 575V AC incoming line)
1005V DC bus (equivalent to 711V AC incoming line)
210V DC bus (equivalent to 150V AC incoming line)
390V DC bus (equivalent to 275V AC incoming line)
487V DC bus (equivalent to 344V AC incoming line)
390V DC bus (equivalent to 275V AC incoming line)
100 milliseconds
0.5 seconds minimum, 2 seconds typical
2
I
t protection - 150% for 60 seconds, 200% for 3
seconds (Provides Class 10 protection)
200% hardware limit, 300% instantaneous fault
Phase-to-ground on drive output
Phase-to-phase on drive output
1000 m (3300 ft) max. without derating. Above 1000 m
(3300 ft) derate 3% for every 305 m (1000 ft).
–10 to 50° C (14 to 122° F)
–10 to 40° C (14 to 104° F)
Heatsink:
Drive:
0.4 kW (0.5 HP) drives and all Flange and Plate drives
All other drive ratings
–40 to 85 degrees C (–40 to 185 degrees F)
Important: Drive must not be installed in an area
where the ambient atmosphere contains volatile or
corrosive gas, vapors or dust. If the drive is not going
to be installed for a period of time, it must be stored in
an area where it will not be exposed to a corrosive
atmosphere.
0 to 95% non-condensing
15G peak for 11ms duration (±1.0 ms)
1G peak, 5 to 2000 Hz
200-240V ±10%
380-480V ±10%
460-600V ±10%
48-63 Hz
Three-phase input provides full rating. Single-phase
operation provides 35% rated current.
0.98 across entire speed range
100,000 Amps Symmetrical
Determined by AIC Rating of installed fuse/circuit
breaker
Isolated Gate Bipolar (IGBT)
–10 to 40° C (14 to 104° F)
–10 to 50° C (14 to 122° F)
English-5

Publicidad

Tabla de contenido
loading

Tabla de contenido