Fig. 4 - Model Number; Specifications; Temperature Sensor; General Information - Norcold N180.3 Manual De Servicio

Tabla de contenido

Publicidad

Model Identification, cont'd.
Model Number
N X 3 X .3 IM C BK F R P T

Fig. 4 - Model Number

www.norcold.com
Explanation
1
N = Norcold
X = Sequence number indicating
2
custom features / aftermarket XA /
3 = Approximate storage volume in
3
cubic feet
X = Sequence number indicating
4
custom features
Blank = 2-Way Model
5
.3
= 3-Way Model
Blank = Without icemaker
6
IM
= With icemaker
7
Low Ambient Operation:
Blank=Not Equipped
C=Is Equipped
Door design:
8
Blank = Insert panel
SS=Stainless steal wrapped BK=Black
wrapped
WH=White wrapped
WPM=Pewter Royce wrapped
Fan:
9
Blank=No fan
F = Equipped (1 Fan)
F2 = Equipped (2 Fans)
J = Equipped (1) High Velocity Fan
Door swing:
10
L = Left-hand door swing
R = Right-hand door swing
11
P=Black acrylic door panels
Packaging Type:
12
Blank=Corrugated packaging
T = Returnable packaging
M4 = 4-unit multi-pack
M6 = 6-unit multi-pack
M8 = 8-unit multi-pack

Specifications

Rough Opening Dimensions (H x W x D)
..................... 20.63 - 20.76 in. x 25.63 - 25.76 x 16.88 in.
DC Power
DC input voltage requirements ...........11.5VDC to 15.4VDC
DC Heater current draw .............. 11.7 Amps at 12 volts DC
................................................. 13.6 Amps at 14 volts DC
AC Power
AC input voltage requirements ..............108VAC to 132VAC
AC Heater current draw ...............1.3 Amps at 110 volts AC
..................................................1.4 Amps at 120 volts AC
Propane Gas
Operating pressure (Input pressure to gas valve)
........................................11" W.C Gas Supply + 0.5 W.C.
Burner rating (Heat output) ................ 640 Btu/h @ 11" W.C.
Burner orifice size ........................................................ LP10
Gas ignition........................ Piezo igniter with flame sensing
Electrode tip-to-burner gap ............................... 1/8" to 3/16"
Off-Level Operating Limits
Side-to-side ......................................... 6 degrees-maximum
Front-to-back ....................................... 3 degrees-maximum

Temperature Sensor

Thermostat capillary tube-fin mounted (between 2nd and
3rd fin from the rear)

General Information

To confirm that installation is adequate, check for:
■ Adequate ventilation - refer to "Ventilation Requirements."
■ Both gas and electrical components installed and operating in a
safe condition.
■ Adequate seal between refrigerator mounting flange and cut-out
opening.
■ Installed on a solid floor (not on carpet) and secured.
WARNING
!
ATTENTION
5
This refrigerator is not intended to be
operated as a free standing unit (i.e.
where the products of combustion are not
completely isolated from the living area) or
installed in such a way as to conflict with
these installation instructions. Unapproved
installations could result in safety risks or
performance problems.