Greenlee CM-410 Manual De Instrucciones página 12

Ocultar thumbs Ver también para CM-410:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
Accuracy
Refer to "Specifications" for operating conditions and temperature coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount)
at 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% to 80% relative humidity.
Amps
.
Measurement.
.
Range.
0.0 to 40.0 A
40.0 to 200.0 A
201 to 400 A
AC.Voltage
. Measurement.
.
Range.
200.0 V
600 V
DC.Voltage
.
Measurement.
.
Range.
200.0 V
600 V
Resistance
.
Measurement.
.
Range.
200.0 Ω
2.000 kΩ
20.00 kΩ
200.0 kΩ
2.000 MΩ
20.00 MΩ
1
± (1.9% + 1 A)
± (1.9% + 0.5 A)
± (1.9% + 5 A)
.
Accuracy.
± (1.5% + 0.5 V)
± (1.5% + 5 V)
± (1.0% + 0.2 V)
± (1.0% + 2 V)
± (1.2% + 0.5 Ω)
± (0.7% + 0.002 kΩ)
± (0.7% + 0.02 kΩ)
± (0.7% + 0.2 kΩ)
± (1.0% + 0.002 MΩ)
± (1.9% + 0.05 MΩ)
.
Accuracy.
Frequency.
Range.
50 to 500 Hz
50 to 500 Hz
.
Accuracy.
Accuracy
Frequency.
Range
50 to 60 Hz
50 to 60 Hz
50 to 60 Hz
Input.
Impedance
10 MΩ //
100 pF max
Input. .
Impedance
10 MΩ //
100 pF max

Publicidad

Tabla de contenido
loading

Tabla de contenido