For the U.K. and the Republic of Ireland only
• The wires in the mains lead are coloured in accor-
dance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured Green-and-Yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire
which is coloured Blue must be connected to the
terminal which is marked with the letter "N" or
coloured Black. The wire which is coloured Brown
must be connected to the terminal which is
marked with the letter L or coloured Red.
• Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut off if it is
moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
• The non-rewirable plug must never be used
without a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be ob-
tained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 10A and approved to BS
1362.
5a. WATER SUPPLY AND DRAIN
CONNECTIONS (DCM-230FE)
(For the U.K. only, the connections must be in accor-
dance with current requirements of the Model Water
Byelaws 1986 SI No. 1147)
• Only potable water should be used for this ice
dispenser.
• External filters, strainers or scale treatment may
be required, depending on water quality.
• Water supply pressure should be minimum
0.5 bar and maximum 8 bar. If the pressure
exceeds 8 bar, use a pressure reducing valve.
Do NOT throttle back the supply tap.
• A plumbing permit and services of a licensed
plumber may be required in some areas.
• The ice dispenser drain is gravity flow, so ensure
the drainpipe has an adequate pitch or fall.
or
• Water should drain into an open trap.
1) By means of a suitable spanner or wrench, tighten
the 1/2-3/4 nipple (accessory) into the 1/2 FTP
fitting and 3/4-3/4 nipples (accessory) into the
3/4 FTP fittings on the rear of the ice dispenser
as indicated. P.T.F.E. tape and/or a suitable
sealing compound should be used to obtain a leak-
free joint.
Note: Jointing compounds should be approved
and suitable for potable water use.
2) Attach angled end of white flexible inlet hose
(accessory) to free end of 1/2-3/4 nipple ensuring
rubber sealing washer is correctly positioned.
Hand tighten sufficiently to provide leak free joint.
3) Attach the other end of inlet hose to the water tap,
noting washer is correctly positioned before hand
tightening as above. See Fig. 3b.
4) Attach grey flexible outlet hoses (accessory) to
free end of 3/4-3/4 nipples, confirming fitment of
rubber washers before finally hand tightening the
joints. These pipes can be cut to length as
necessary to suit position of main drain.