Operating Instructions SATA vision 2000
EN
Description
Max. operating pressure
Min. volumetric flow
Max. volumetric flow
Operating temperature
Storage temperature
Max. tube length
Noise level with minimum-
volumetric flow
Weight of breathing protection
hood
Weight of activated charcoal ab-
sorber
Weight of belt unit without activat-
ed charcoal absorber
8. First Use
The breathing protection hood is delivered in an assembled and opera-
tionally ready state.
Check after unpacking:
■ Breathing protection hood damaged.
■ Scope of supply complete (see chapter 5).
8.1. Installation on air supply
Variant 1, 2 and 3
Notice!
Use only approved compressed air supply hose (max. 40 m) with safety
quick-couplers for operation of the breathing protection hood.
Variant 1
142
Variante 1 Variante 2 und 3
170 Nl/min
-20 °C – +60 °C
8,0 bar
240 Nl/min
> 305 Nl/min
-6 °C – +60 °C
40 m
73 dB
470 g
750 g
260 g