Bitstring Of 32 Bits With Time Tag; Bitstring Of 32 Bits 3); Bitstring Of 32 Bits With Time Tag Cp56Time2A - Control Direction; Out Out - Siemens CP 1243-8 IRC Instrucciones De Servicio

Ocultar thumbs Ver también para CP 1243-8 IRC:
Tabla de contenido

Publicidad

Formato (memoria
Tipo de punto de datos
necesaria)
Single command with time tag
CP56Time2a
Byte
Step position information
Step position information with time
tag CP56Time2a
Entero (16 bits)
Measured value, normalized value
Measured value, normalized value
with time tag CP56Time2a
Measured value, scaled value
Measured value, scaled value with
time tag CP56Time2a
Set point command, normalised
value
Set point command, scaled value
Set point command, normalised
value with time tag CP56Time2a
Set point command, scaled value
with time tag CP56Time2a
Entero (32 bits)
Bitstring of 32 bits

Bitstring of 32 bits with time tag

CP56Time2a
Integrated totals
Integrated totals with time tag
CP56Time2a
Bitstring of 32 bits
Bitstring of 32 bits with time tag
CP56Time2a - control direction
Número en coma
Measured value, short floating point
flotante (32 bits)
number
Measured value, short floating point
number with time tag CP56Time2a
Set point command, short floating
point number
Set point command, short floating
point with time tag CP56Time2a
Bloque de datos
Double-point information
(1...2 Bit)
2)
Double-point information with time
tag CP56Time2a
Double command
Regulating step command
Double command with time tag
CP56Time2a
Regulating step command with time
tag CP56Time2a
CP 1243-8 IRC
Instrucciones de servicio, 02/2018, C79000-G8978-C385-03
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1) 2)
1) 2)
Tipo IEC
Sentido
Tipos de datos
S7
<58>
out
Bool
<5>
in
Byte, USInt
<32>
in
Byte, USInt
<9>
in
Int
<34>
in
Int
<11>
in
Int
<35>
in
Int
<48>
out
Int
<49>
out
Int
<61>
out
Int
<62>
out
Int
<7>
in
UDInt, DWord
<33>
in
UDInt, DWord
<15>
in
UDInt, DWord
<37>
in
UDInt, DWord
<51>
out
UDInt, DWord
<64>
out
UDInt, DWord
<13>
in
Real
<36>
in
Real
<50>
out
Real
<63>
out
Real
<3>
in
<31>
in
<46>
out
<47>
out
<59>
out
<60>
out
Configuración
4.18 Puntos de datos
Área de operan-
dos
Q, M, DB
I, Q, M, DB
I, Q, M, DB
I, Q, M, DB
I, Q, M, DB
I, Q, M, DB
I, Q, M, DB
Q, M, DB
Q, M, DB
Q, M, DB
Q, M, DB
I, Q, M, DB
I, Q, M, DB
I, Q, M, DB
I, Q, M, DB
Q, M, DB
Q, M, DB
Q, M, DB
Q, M, DB
Q, M, DB
Q, M, DB
DB
2)
DB
2)
DB
2)
DB
2)
DB
2)
DB
2)
143