54 | ACS 752 | Operation
10.4
Automatic service
i
This function enables the automatic performance of
the service phases Recovery, Vacuum and Filling.
i
The service parameters (filling quantity and type of
refrigerant and fresh oil) can be taken from the data-
base and used for the "Automatic Service".
!
The service parameters (vacuum generation time,
recharge quantity, oil and refrigerant type) can be
found in the owner's manual or the vehicle repair
manual and must be observed.
!
For vehicles with only one service connection the
service phase "Filling" should be performed in the
"Manual service" mode.
!
For vehicles with only one service connection the
manufacturer's recommended procedure must be
followed.
<Automatic> key
!
Observe the ACS 752 menu prompting.
1. Connect the HP and LP service hoses to the vehicle
air conditioning system.
2. Open the valves on both service hoses.
3. Call up start screen.
4. Press <AUTOMATIC>
Dialog Customer data is displayed.
5. Select
$
Add the customer data and confirm with <OK>.
$
Press
to add a vehicle from the database and
follow messages on screen.
i
Press <ESC> to return to the start screen.
i
To continue without customer data press <OK> with-
out adding any data.
Dialog ports and quantity is displayed.
|
S P00 D00 159
2019-03-01
6. Press <1>, <2> or <3> to select the used service
hoses.
7. Press <4> ... <8> to enable/disable and to input the
quantity of oil, UV dye and refrigerant and to define
the time for vacuum.
i
Input the quantity with <0 – 9>, use z r to delete
existing values. Confirm with <OK>.
i
For PAG and POE, you must enter the quantity to
be added additionally to the previously extracted
quantity.
i
The added oil quantity can only be set in automatic
mode. If the value is "0 ml", the quantity of compres-
sor oil added to the compressor corresponds to
the quantity of the recovered oil. If the value for the
added oil quantity is "20 ml", the quantity of com-
pressor oil added to the compressor corresponds to
the quantity of recovered oil plus 20 ml.
8. Press <OK> to continue and follow messages on the
screen.
"
ACS 752 performs "Automatic service".