O p e r a t i o n

SEMI-ELECTRIC BED OPERATION

NOTE– Semi-electric beds use a four-function pendant for head and foot functions. The Single
Crank and Two Crank beds use a hand crank for hi/lo operation; Set Height beds do not
have hi/lo operation.
1. Make sure the pendant is properly plugged into the control box and the power cord is
plugged into the wall outlet. Press desired function button in pendant and operate
each function from beginning to end and back again, as instructed below. They
should operate smoothly, without sticking or hesitating.
2. If problems arise, check all electrical connections and mechanical hook ups.
3. The Set Height bed (IC-5110) has head and foot functions, but the height of the bed
is not adjustable.
4. To raise entire height of Single Crank Hi/Lo bed (IC-5310), turn crank 2 clockwise.
To lower, turn crank 2 counterclockwise (Figure 44).
5. To raise entire height of Two Crank Hi/Lo bed ends individually (IC-5210), insert crank
4 (not shown) into head and foot end and turn clockwise. To lower, turn crank coun-
terclockwise.
6. To raise the head end of all semi-electric beds, press the "HEAD UP" button on the
hand pendant. To lower head end, press the "HEAD DOWN" button (Figure 45).
7. To raise the foot end of all semi-electric beds, press the "FOOT UP" button on the
hand pendant. To lower foot end, press the "FOOT DOWN" button.

FULL-ELECTRIC BED OPERATION

NOTE– Full-electric beds use a six-function pendant for all operation.
1. Make sure the pendant is properly plugged into the control box and the power cord is
plugged into the wall outlet. Press desired function button in pendant and operate
each function from beginning to end and back again, as instructed below. They
should operate smoothly, without sticking or hesitating.
2. If problems arise, check all electrical connections and mechanical hook ups.
3. To raise the entire height of full-electric beds, press the "BED UP" button on the
hand pendant. To lower the height, press the "BED DOWN" button (Figure 46).
4. To raise the head section of full-electric beds, press the "HEAD UP" button on the hand
pendant. To lower the head section, press the "HEAD DOWN" button.
5. To raise the foot section of full-electric beds, press the "FOOT UP" button on the hand
pendant. To lower the foot section, press the "FOOT DOWN" button.

LOCKING/UNLOCKING CASTERS

1. If two locking casters are not included with your bed, contact your local Sunrise
Medical dealer.
2. To engage the two wheel locks, push wheel locking tab down until it locks into place.
3. To disengage the wheel locks, push wheel locking tab up until it is released from the
locked position.
RISK OF INJURY. Always keep wheels locked during transfers. Check wheel locks
for correct locking operation before each use.
EMERGENCY CRANK FOR SEMI AND FULL ELECTRIC BEDS
Semi-electric and full-electric beds are equipped with an emergency crank. In the event of
power failure or motor failure, you can still operate any of the bed functions by turning the
motor shaft or the center shaft with the emergency crank (Figure 47).
POSSIBLE INJURY. Unplug power cord from wall outlet before using emergency
crank. Injury could result if power resumes while cranking.