7.2 Installation conditions
• The fl oor and installation area must be fl at and level.
– Difference in height ≤ 1 mm (DIN 18202, tab. 3 - r.4).
– Compressive strength 25 N/mm
• Within 5 m of the installation area, a socket with a fuse of maximum 230 V/16 A
must be available. Alternatively, for example, a fi xed, protected installation with
connecting cables (see page 19 / MPS catalog).
• There cannot be any objects (e.g. forks) under the lifting gears. Lifting or lowering
the lifting gear against obstacles or stops (so-called block travel) is not permitted.
• The distance between the work table and moving parts of the case lifter must
be ≥ 120 mm (see page 14).
Fig. 10:
Installation requirements for the electrical case lifter
7.3 Required tools
• Hex wrench SW17.
• Hex socket head cap screw SW6
• Spirit level
• Hammer drill with drill for stone / concrete, ø14.
2
(concrete B I, strength class B 25 DIN 1045).
3 842 358 709/2016-07, MPS, Bosch Rexroth AG
Installation
21/52
358 709-07