Shutoff Delay; Filter Saturation Alarm; Alarm Messages - Franke DROP - FDR 900 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
EN

Shutoff delay

This function allows you to temporarily continue
filtering and extracting residual smoke after the
cooking has stopped.
Switching on
Briefly press
X
Z
Activates motor shutoff deferred by 30
minutes.
Display: Alternately displays the speed of the
extraction motor and the time remaining until
motor shutoff. The point at the bottom to the
right flashes.
Switching off
Briefly press
X
Z
 Turns the off the „delayed stop" function

Filter saturation alarm

The alarm tells you when the grease filters and the
odour filters need to be cleaned or replaced (for the
non-washable odour filters).
Activating the alarm „filter saturation"
Depending on the type of control keyboard, the
„Filter saturation" alarm may need to be activated if
your appliance is a recycling
or clean-air type.
Contact Customer Service.
X
Z
Deactivating the alarm „filter saturation"
Contact Customer Service.
X
Z
Resetting the alarm „filter saturation"
24
Briefly press
X
Z
F
 Resets the filter alarm once triggered.
.
.
.
FDR 900/1200

Alarm messages

Display: Displays «FG» which signals the need
to wash the grease filters every 100 hours of
operation.
Display: Displays «EF» which signals the need
to wash the grease filters and replace or wash
the odour filters (according to their type), every
200 hours of operation.
These «FG and EF» signals are only visible
when the motor and the lighting are off.
– 16 –

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Drop - fdr 1200