4. Technical data

Range
Accuracy at 25 °C
Front beam (horizontal):
Perpendicular beam (horizontal):
Angle (horizontal):
Plumb beams:
Self-leveling time
Laser class
Beam diameter
Self-leveling range
Automatic switch-off
Operating status indicators
Power supply
Battery life at 25 °C [+77 °F]
Operating temperature range
Storage temperature
Protection against dust and water spray
Tripod thread
Weight
Dimensions: closed
opened
*Range depends on the ambient light conditions.
Rigth of technical changes reserved.

5. Safety precautions

5.1 Basic information concerning safety

In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
5.2 Correct use of the tool
The tool is designed for predominantly indoor use for
determining and checking differences in the height of
points in the horizontal plane, vertical lines, alignment
and for marking plumb points. When used for outdoor
applications, care must be taken to ensure that the con-
ditions under which the tool is used correspond to the
conditions encountered indoors.
Examples of applications:
Transferring datum marks and height marks.
Marking out the position of partitions (at right angles
and in the vertical plane).
Aligning equipment/installations and other structural
elements in three axes.
Checking and transferring right angles.
Transferring points marked on the floor to the ceiling.
Printed: 07.07.2013 | Doc-Nr: PUB / 5070096 / 000 / 00
30 m*
± 3 mm at 10 m (
1
/
in at 30 ft)
8
1
± 3 mm at 10 m (
/
in at 30 ft)
8
90° ± 60"
± 3 mm at 10 m (
1
/
in at 30 ft)
8
~ 3 seconds
Class 2, visible, 635 ± 10 nm @ 25 °C
(IEC825-1; EN 60825-01:2003; CFR 21 § 1040 (FDA))
≤ 3 mm @ 5 m @ 25 °C/≤ 12 mm @ 20 m @ 25 °C
± 5°
Activated after 15 min.
LED + laser beams
4 x alkaline batteries, size AA
Alkaline batteries: > 40 h with 2 beams (horizontal or
vertical) in use
–10 °C up to +40 °C (± 2) °C/+14 °F up to 104 (± 4) °F
–20 °C up to +63 °C/–4 °F up to 145 °F
IP 54 (in accordance with IEC 529) except battery
compartment
" and UNC
"
5
1
BSW
/
/
8
4
660 g without batteries
ca.138 (L) x 51 (W) x 89 (H) mm
ca.164 (L) x 51 (W) x 126 (H) mm
5.3 Misuse of the tool
Do not use the tool unless its accuracy has been pre-
viously checked.
The tool and its ancillary equipment may present
hazards when used incorrectly by untrained per-
sonnel or when used not as directed.
Do not open the casing of the tool.
To avoid the risk of injury, use only original Hilti acces-
sories and additional equipment.
Modification of the tool is not permissible.
Observe the information printed in the operating
instructions concerning operation, care and main-
tenance.
Do not render safety devices ineffective and do not
remove information and warning notices.
Keep laser tools out of reach of children.
en