WATER CONDENSATION DRAINAGE (CONTINUED)
IMPORTANT: The water cannot be drained using the continuous drain option in heating* mode.
In Heating mode, the internal water tank collects condensation faster and may require more
frequent emptying of the tank in more humid rooms. It is recommended to use the heating mode in a
room with 50 % humidity or lower. Avoid operating moisture-creating products or appliances such as
a humidifier or a kettle when using the unit in heating mode.
Continuous Draining for Dehumidifier Mode
While using the unit in dehumidifier mode, continuous
drainage is recommended.
1.
Unplug the unit from power source.
2.
Remove the upper rubber drain plug. While doing this
operation some residual water may spill so please
have a pan to collect the water.
3.
Connect the drain connector to a 1/2" hose or
standard garden hose (not included). See diagram.
4.
The water can be continuously drained through the
hose into a floor drain or sink.
5.
You can now turn on the unit.