Operation of the Unit
Max. ramp current
GB
Max. constant current
GB
GB- 20
This function protects the frequency inverter against switching off through
overcurrent during the acceleration ramp. When the ramp reaches the
adjusted value,it is stopped so long until the current decreases again.
CP.3 displays "LAS" at active function.
Adjustment range:
Resolution:
Factory setting:
This function protects the frequency inverter against switch off through
overcurrent during constant output frequency. When exceeding the
adjusted value, the output frequency is reduced until the value drops
below the adjusted value. CP. 3 displays "SSL" at active function.
Adjustment range:
Resolution:
Factory Setting:
Utilization
CP.24
CP.25
on
off
on
off
f
real
f
set
0...200 %
1 %
140 %
0...200 % (off)
1 %
200 % (off)
t
LAD-stop
t
Current limit
t
t