Analog ouput 1 / Function
Analog output 1 /
Amplification
CP.29 defines the function of analog output 1.
Value Function
0
Absolute actual value (CP.1)
1
Absolute set value (CP.2)
2
Actual value (CP.1)
3
Set value (CP.2)
4
Output voltage (CP.9)
5
Intermediate circuit (DC) voltage (CP.7)
6
Apparent current (CP.4)
7
Active current
8-10
Only application-mode
11
Absolute active current
12
Power module temperature
13
Motor temperature
14-18 Only application-mode
19
Ramp output frequency
20
Absolut ramp output frequency
21
Only application-mode
Adjustment range:
Resolution:
Factory setting:
Note:
With the amplification the output voltage of the analog output can be tuned
the signal to be given out. An amplification of 1 corresponds to ±100 %
= +10 V.
Adjustment range:
Resolution:
Factory setting:
out
100%
CP.30
-100%
-100%
Operation of the Unit
2 x rated current = 100%
±2 x rated current = ±100%
2 x rated current = 100%
0...12
(Basic + Compact)
0...21
(General)
Enter-Parameter
-20,00...20,00
0,01
1,00
Setting aid:
The analog output shall give
10V
out +10 V at 70 Hz instead
at 100 Hz:
CP.30 =
in
100%
100Hz = 100%
100Hz = 100%
±100Hz = ±100%
±100Hz = ±100%
500V = 100%
1000V = 100%
100 °C = 100%
100 °C = 100%
±100Hz = ±100%
100Hz = ±100%
1
2
100 Hz
–––––– = 1,43
70 Hz