7. Programming output timing (lights mode):

Step
Action
1
Press P1
2
Press and hold down P1 for more than 3 s
3
Press P1 as many times as the desired number
of hours of output activation:
1 press => 0 hours
2 presses => 1 hour
...
10 presses => 9 hours
4
Confirm the hours of operation by keeping P1
pressed for more than 3 s
5
Press P1 as many times as the desired number
of minutes of motor activation:
1 press => 0 minutes
2 presses => 1 minute
...
60 presses => 59 minutes
6
Confirm the minutes of operation by keeping P1
pressed for more than 3 s
7
Press P1 as many times as the desired number
of seconds of motor activation:
1 press => 0 seconds
2 presses => 1 second
...
60 presses => 59 seconds
8
Confirm the seconds of operation by keeping P1
pressed for more than 3 s to end the procedure
Note: If the time is not confirmed, the previously set time is kept.
Note: If you set a time of 0 h, 0 min and 0 s, the default time of 0 h, 1 min and 0 s is automatically set
VIMAR group
Signal
The buzzer will beep once
every 2 s
x 1
The buzzer will beep
> 3 s
The buzzer will beep 2 times
whenever the button is
pressed
x n
The buzzer will beep
> 3 s
The buzzer will beep 3 times
whenever the button is
pressed
x n
The buzzer will beep
> 3 s
The buzzer will beep 4 times
whenever the button is
pressed
x n
The buzzer will beep
> 3 s
EN
x 1
x 1
x 2
x 1
x 3
x 1
x 4
x 1
15

Publicidad

Tabla de contenido
loading

Tabla de contenido