Vimar ELVOX ECGF Manual De Instrucciones Para La Conexión Y El Uso página 18

Microcentral para instalación tras mecanismo para motores tubulares
Ocultar thumbs Ver también para ELVOX ECGF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
ECGF
8. Remote control programming:
Step
Action
1
Press P1 2 times
2
Press and hold down P1 for more than
3 s
3
Press P1 to select the setting of the
micro control panel as per the buzzer
signal.
4
Press the push button of the remote
control you want to save.
5
To learn an additional remote control (or
button) repeat from point 3
6
Wait for the 10 s timeout to exit the
procedure.
Exiting from the procedure is signalled
by the buzzer
Note: When trying to save a button that has already been saved, the buzzer will beep 5 times
Note: If the memory is full the buzzer will emit 10 long beeps
The remote control button to be saved can be set in the following ways
Operating
Command
modes
configuration
Lights
Output 1
Output 2
16
Signal
The buzzer will beep 2 times every
2 s
x 2
The buzzer will beep
> 3 s
The buzzer will beep a number of
times equal to the set mode
0
Step by step
1
Up-stop
2
Down-stop
3
Step by step UP
4
Up UP
5
Down UP
6
Stop
7
Up
8
Down
The buzzer will beep 2 times
... 10 s ... The buzzer will beep
Description
Activation of output 1 according to the set mode (one-position stable, two-
position stable or timed)
Activation of output 2 according to the set mode (one-position stable, two-
position stable or timed)
EN
x 2
x 1
Output 1
1
Output 2
2
3
4
5
6
7
8
9
x 2
x 1

Publicidad

Tabla de contenido
loading

Tabla de contenido