ECGF
6. Configuration of outputs (lights mode):
Step
Action
1
Press P1 3 times to configure output 1
Press P1 4 times to configure output 2
2
Press and hold down P1 for more than 3 s
3
Press P1 to select the setting of the micro
control panel as per the signal and the buzzer.
4
Press and hold down P1 for more than 3 s
The type of output operation can be set as follows:
Operating modes
configuration
(default setting)
Lights
14
Command
Description
Monostable
The selected output is activated only while the control button is pressed.
If the output is already active (eg, output active for wired control with
subsequent remote control) the second command is ignored.
Note: If no voltage is present, when the power supply comes back on the
control panel will maintain the output status (if the local input status is not
changed during the power failure)
Bistable
The outputs are controlled in the following way:
First command:
Second command: => output deactivated
In addition, when the local switch is on and its output is active, if you press
the corresponding button on the remote control the output will deactivate;
upon switching off the switch again, the output will be reactivated.
Note:
If no voltage is present, when the power supply comes back on the control
panel will maintain the output status (if the local input status is not changed
during the power failure).
Timed
The selected output is activated when you press the remote control button
and it remains active for the set time interval.
The output can be deactivated by pressing the button, after a minimum
time of 5 seconds.
The output is controlled in an identical way with the wired push button and
in a similar manner with the switch, as follows:
- the switch's change in state is equivalent to pressing the remote control
button and causes the activation/deactivation of the output, if a minimum
of 5 s has passed between the two changes in state.
Note:
If no voltage is present, when the power supply comes back on the control
panel will keep the outputs deactivated.
Signal
n = 3
n = 4
x n
The buzzer will beep
> 3 s
m = 1 beep
m = 2 beeps => Bistable
m = 3 beeps => Timed
x n
The buzzer will beep
> 3 s
=> output activated
EN
=> Output 1
=> Output 2
=> Monostable
x n
x 1
x m
x 1