Lowering The Vehicle; Behaviour In Cases Of Error; Emergency Discharge - Nussbaum POWER LIFT HF 3S 5000 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.4
Lowering the vehicle
Check that there are no people or objects in the
!
hazardous area of the lift.
• Lower the vehicle to the desired working height.
Pull the operating lever (9) slowly backwards =
"LOWER" (19).
i
For heavier vehicles, lift it slightly before lowering
to prevent an "sticking" and any corresponding
jolt during lowering.
• The entire lowering process must be observed.
• Lowering speed can be seamlessly adjusted.
• Once the lift is detected in the lowest position,
swing out the lifting arms to the start position (see
image 028).
• Move the vehicle out of the lift.
Putting down into the locking mechanism: Press
!
button (16) Fig. 009 and simultaneously pull the
operating lever (19).
CE Stop:
When the lift is lowered, it stops at a height of ap-
prox. 20 cm above the floor. To lower the lift com-
pletely, press button (16) and simultaneously pull
the control lever (19).
6

Behaviour in cases of error

Defective operational readiness of the lift may be
due to a simple error. Check the lift for the listed
sources of error.
If the error cannot be removed after an inspection
to the named causes, then inform customer service
or your dealer.
Independent repair work on safety
devices of the lift and checking the
electrical system may only be done
by specialists.
Problem: The lift cannot be raised
Possible causes:
No power supply
Only 2 phases active
OPI-POWER LIFT HF 3S 5000 - HYMAX HF 3S 5000-V1.1-DE-EN-FR-ES-IT
Remedy:
Check the power supply
Do an on-site check with
a qualified electrician
The main switch is not
switched on, or is de-
fective
Defective fuse
Operating lever defec-
tive
Motor has overheated
Motor defective
Insufficient hydraulic oil
available
The vehicle is too heavy Unload vehicle
Problem: The lift cannot be lowered
Possible causes:
The lifting arm has
moved onto an obsta-
cle
Operating lever defec-
tive
CE stop valve is defec-
tive
CE stop switch is active
6.1

Emergency discharge

An emergency discharge is an ac-
cess into the lift controls and may only
be done by experienced specialists.
The emergency discharge must be
done in the following described se-
quence, otherwise it can lead to
damage and hazard to life and limb.
People may not stand in the hazard-
ous area around the lift.
Check the main switch
Check fuses
Check function; Inform
customer service
Let motor cool (cooling
time dependent on am-
bient temperature)
Do an emergency dis-
charge (see Section 7.2);
Inform customer service
Refill new hydraulic oil
Remedy:
Raise the lift and remove
the obstacle
Check function; Do an
emergency discharge
(see Section 6.1); Inform
customer service
Inform customer service
Push button (16) and pull
the lever (19)
87

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Power lift hf 3s 5000 dgPower lift hf 3s 5000 universalHymax hf 3s 5000Hymax hf 3s 5000 dgHymax hf 3s 5000 universal

Tabla de contenido