Promax MO-180 Manual De Usuario página 154

Modulador sfn/mfn dvb-t/h
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Name
Message
*CFQddddddddd<cr>
CFQ
*?CFQ<cr>
*CFUd<cr>
CFU
*?CFU<cr>
*S10d<cr>
S10
*?S10<cr>
*Z10d<cr>
Z10
*?Z10<cr>
*PPSd<cr>
PPS
*?PPS<cr>
*Z1Pd<cr>
Z1P
*?Z1P<cr>
*PFId<cr>
PFI
*?PFI<cr>
*PIDnndddd<cr>
PID
*?PIDnn<cr>
04/2008
Answer
Description and Format
Sets the NIT Centre Frequency
locally (CFU needed to update it in
the TS)
'ddddddddd' decimal digits
d: value in Hz
*CFQdddddddd
Asks for the local NIT Centre
d<cr>
Frequency
'd' as before
Replace the incoming NIT Centre
Frequency with the Local Centre
Frequency
'd' decimal digit
0: No 1: Yes
*CFUd<cr>
Asks for the NIT Centre Frequency
selection
'd' as before
Sets the 10MHz synchronization
mode
'd' decimal digit
0: External 1: Internal 2: Auto1 3:
Auto2
*S10d<cr>
Asks for the 10MHz synchronization
mode
'd' as before
Selects the 10MHz input impedance
'd' decimal digit
0: High 1: 50Ω
Asks for the 10MHz input
*Z10d<cr>
impedance
'd' as before
Selects the active edge for the 1PPS
input
'd' decimal digit
0: Rising 1: Falling
Asks for the active edge
*PPSd<cr>
'd' as before
Selects the 1PPS input impedance
'd' decimal digit
0: High 1: 50 Ω
*Z1Pd<cr>
Asks for the 1PPS input impedance
'd' as before
Sets PID filtering ON/OFF
'd' decimal digit
0: OFF 1: ON
*PFId<cr>
Asks for the PID filtering state
'd' as before
Sets one of 16 PID's for filtering
'n', 'd' decimal digit
n: value between 0 and 15
d: value between 0 and 8191
*PIDdddd<cr>
Asks for the value of the PID
'n' and 'd' as before
USER'S MANUAL. MO-180
Page 84

Publicidad

Capítulos

Tabla de contenido
loading