Installer Settings
Install menu
Function
Selection
SET
FOCUS
NOW
COMM
ON, OFF
DEFAULTS
Select submenu
EXIT
Adjustment procedure DC-iris Lens:
1.
Unlock the focus locking screw.
2.
SET BACK FOCUS NOW is highlighted in the menu.
3.
Turn the focus adjustment as required.
4.
Lock the focus locking screw.
5.
Exit the menu selection.

Defaults submenu

Function
Selection
ALL
DEFAULTS
EXIT

Camera control communication

This camera is equipped with a coaxial communications transceiver. In
combination with VP-CFGSFT, the camera can be adjusted from the head-
end side of the coaxial cable. All menus can be accessed remotely giving
full control of the camera. With this communication it is also possible to
disable the local keys on the camera. To avoid loss of communication on
an installed camera, the Communication ON/OFF selection is not
available while using remote control. This function can only be accessed
with the camera buttons.
Bosch Security Systems | 2005-11 | V1.0
Description
Forces the lens to fully open the iris. Adjust the lens
focus now.
Bilinx communication ON/OFF
Return all settings for all modes to factory defaults
Exit the menu
Description
Select to restore the factory defaults. A confirmation
screen appears. Allow 5 seconds for the camera to
optimize the picture after a mode reset.
Exit the menu