AREA
1, 2, 3, 4,
Select submenu
ACTIVE
ON, OFF
MOTION
Press SELECT to
reset indicator
SENS
EXIT
Note
If VMD areas overlap, motion is only detected in the area with the lowest
sequence number.

Defaults submenu

Function
Selection
MODE
DEFAULTS
EXIT
Bosch Security Systems | 2003-10 | V0.5
• It is possible to set 4 motion sensitive areas (per
MODE).
• Press SELECT to enter the area set-up menu.
Every area can be enabled individually by
selecting YES.
Indicates the peak of measured motion in the
selected area
Use the LEFT/RIGHT keys to set the SENSitivity
for motion to the desired level. Motion above this
level triggers alarm.
Return to MODE menu
Description
Select to restore the factory defaults. A
confirmation screen appears. Allow 5 seconds for
the camera to optimize the picture after a mode
reset.
Return to MODE menu