10
Wire diameter
In synergy, allows selection of the wire diameter used
(mm).

3.3.1 Set up

Permits set up and adjustment of a series of additional param-
eters for improved and more accurate control of the welding
system.
The parameters present at set up are organised in relation to the
welding process selected and have a numerical code.
Entry to set up: by pressing the encoder key for 3 sec. (the
central zero on the 7-segment display confirms entry).
Selection and adjustment of the required parameter: by
turning the encoder until displaying the numerical code relating
to that parameter. If the encoder key is pressed at this point,
the value set for the parameter selected can be displayed and
adjusted.
Exit from set up: to quit the "adjustment" section, press the
encoder again.
To exit the set up, go to parameter "O" (save and quit) and press
the encoder.
List of set up parameters
0
Save and quit
Allows you to save the changes and quit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
90
Reset XE (Easy Mode)
91
Reset XA (Advanced Mode)
92
Reset XP (Professional Mode)
99
Reset
Allows you to re-set all the parameters to the default
values and restore the whole system to the conditions
predefined by Selco.
90
Reset XE (Easy Mode)
It allows manual MIG welding with the adjustment of
the motor slope.
0
Save and quit
Allows you to save the changes and quit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
5
Motor ramp
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 2.0s, Default 250ms
18
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum off, Maximum 2.0s, Default 80ms
25
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 500ms, Maximum 99.9s, Default off
26
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 500ms, Maximum 99.9s, Default off
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
91
Reset XA (Advanced Mode)
It allows manual MIG and synergic MIG ("MIG
ADVANCED WELDING").
0
Save and quit
Allows you to save the changes and quit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
3
Pre-gas
Allows you to set and adjust the gas flow prior to spark-
ing of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum off, Maximum 99.9s, Default 10ms
4
Soft start
Permits adjustment of the wire feed speed in the phases
prior to sparking.
Given as a % of the wire speed set.
Permits sparking at reduced speed, therefore softer and
with fewer splashes.
Minimum 10%, Maximum 100%, Default 50%
5
Motor ramp
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0s, Default 250ms
18
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum off, Maximum 2.0s, Default 80ms
20
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 99.9s, Default 2.0s
25
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 500ms, Maximum 99.9s, Default off
26
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 500ms, Maximum 99.9s, Default off
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
92
Reset XP (Professional Mode)
It allows manual MIG and synergic MIG ("MIG
PROFESSIONAL WELDNIG").
0
Save and quit
Allows you to save the changes and quit the set up.
27